COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA

The use of refrigeration machines is currently needed by humans due to the increasing effects of global warming. This cooling machine is used in commercial buildings in Indonesia. The air conditioning system used in these commercial buildings certainly requires a lot of energy so that energy savings...

Full description

Saved in:
Bibliographic Details
Main Author: Bayu Tresna Rasidinata, Raden
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/68922
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:68922
spelling id-itb.:689222022-09-19T14:26:23ZCOMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA Bayu Tresna Rasidinata, Raden Indonesia Final Project air conditioning system, variable refrigerant flow, air cooled chiller, cooling performance, VSD, cooling load, fluctuates INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/68922 The use of refrigeration machines is currently needed by humans due to the increasing effects of global warming. This cooling machine is used in commercial buildings in Indonesia. The air conditioning system used in these commercial buildings certainly requires a lot of energy so that energy savings are needed. This research was conducted to obtain information about the cooling performance of three air conditioning systems, namely the variable refrigerant flow system, air cooled chiller without VSD, and air cooled chiller with VSD. This research was conducted as an effort to save energy in commercial buildings. The selection of units and components in each system is carried out through the refrigeration unit catalog based on the cooling load requirements of the building. The analysis carried out to find cooling performance uses the same cooling load data, namely in hotel buildings and fluctuates in one year referring to the 2022 calendar. The variable refrigerant flow air system with the lowest electrical energy consumption of 1,301 MW has the best cooling performance with a value of 1.301 MW. 3.82. Furthermore, the VSD air cooled chiller system with electricity consumption of 2,270 MW has a cooling performance of 2.18. The air cooled chiller system without VSD with electricity consumption of 2,512 MW has a cooling performance of 1.97. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The use of refrigeration machines is currently needed by humans due to the increasing effects of global warming. This cooling machine is used in commercial buildings in Indonesia. The air conditioning system used in these commercial buildings certainly requires a lot of energy so that energy savings are needed. This research was conducted to obtain information about the cooling performance of three air conditioning systems, namely the variable refrigerant flow system, air cooled chiller without VSD, and air cooled chiller with VSD. This research was conducted as an effort to save energy in commercial buildings. The selection of units and components in each system is carried out through the refrigeration unit catalog based on the cooling load requirements of the building. The analysis carried out to find cooling performance uses the same cooling load data, namely in hotel buildings and fluctuates in one year referring to the 2022 calendar. The variable refrigerant flow air system with the lowest electrical energy consumption of 1,301 MW has the best cooling performance with a value of 1.301 MW. 3.82. Furthermore, the VSD air cooled chiller system with electricity consumption of 2,270 MW has a cooling performance of 2.18. The air cooled chiller system without VSD with electricity consumption of 2,512 MW has a cooling performance of 1.97.
format Final Project
author Bayu Tresna Rasidinata, Raden
spellingShingle Bayu Tresna Rasidinata, Raden
COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
author_facet Bayu Tresna Rasidinata, Raden
author_sort Bayu Tresna Rasidinata, Raden
title COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
title_short COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
title_full COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
title_fullStr COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
title_full_unstemmed COMPARATIVE STUDY OF COOLING PERFORMANCE OF AIR COOLED CHILLER AND VARIABLE REFRIGERANT FLOW SYSTEMS IN HOTEL BUILDING AT JAKARTA
title_sort comparative study of cooling performance of air cooled chiller and variable refrigerant flow systems in hotel building at jakarta
url https://digilib.itb.ac.id/gdl/view/68922
_version_ 1822933789682171904