DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES

The development of sensor technology in this modern era is already very rapid with various inventions and developments carried out by experts. Electrochemical biosensors are one of the most widely researched and developed types of sensors because they offer the advantages of low detection limits,...

Full description

Saved in:
Bibliographic Details
Main Author: Arifin Putra Noerrizky, Ivandy
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/69306
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:69306
spelling id-itb.:693062022-09-21T12:32:43ZDESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES Arifin Putra Noerrizky, Ivandy Indonesia Final Project Electrochemical biosensor, SPCE, PET, PVC, PCB, CV, DPV INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/69306 The development of sensor technology in this modern era is already very rapid with various inventions and developments carried out by experts. Electrochemical biosensors are one of the most widely researched and developed types of sensors because they offer the advantages of low detection limits, good sensitivity and specificity, simple structure, and easy operation. Electrochemical biosensors work on the principle of three electrodes, the initial form of which is very large and impractical. Screen-Printed Carbon Electrode (SPCE) is here to solve this problem and has been widely produced by commercial and industrial, but for a more economical prospect many parties make their own SPCE. In this study, manufacture of SPCE using three different types of substrates is done: Polyethylene Terephthalate (PET), Polyvinyl Chloride (PVC), and Printed Circuit Board (PCB) from the design, fabrication to evaluation stages. The design and fabrication stage is the stage carried out in the physical manufacture of SPCE: Design using spce layer graphics software and printing (base, work electrode, auxiliary electrode, reference electrode). The evaluation stage is the SPCE testing stage of fabricated results in the form of SPCE resistance testing, reference electrode testing, electrochemical measurements using the Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) methods, as well as testing sensor performance by looking at scan rate variations and cycle addition stability. This evaluation stage is also a stage to optimize failures that occur by allowing SPCE to perform better. Comparison of substrates used to see the best substrates that can be developed as SPCE substrates as bioelectrochemists were carried out in this study, SPCE as bioelectrokimia sensors have also been sought linear range values and sensitivities so that further development can be carried out text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The development of sensor technology in this modern era is already very rapid with various inventions and developments carried out by experts. Electrochemical biosensors are one of the most widely researched and developed types of sensors because they offer the advantages of low detection limits, good sensitivity and specificity, simple structure, and easy operation. Electrochemical biosensors work on the principle of three electrodes, the initial form of which is very large and impractical. Screen-Printed Carbon Electrode (SPCE) is here to solve this problem and has been widely produced by commercial and industrial, but for a more economical prospect many parties make their own SPCE. In this study, manufacture of SPCE using three different types of substrates is done: Polyethylene Terephthalate (PET), Polyvinyl Chloride (PVC), and Printed Circuit Board (PCB) from the design, fabrication to evaluation stages. The design and fabrication stage is the stage carried out in the physical manufacture of SPCE: Design using spce layer graphics software and printing (base, work electrode, auxiliary electrode, reference electrode). The evaluation stage is the SPCE testing stage of fabricated results in the form of SPCE resistance testing, reference electrode testing, electrochemical measurements using the Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) methods, as well as testing sensor performance by looking at scan rate variations and cycle addition stability. This evaluation stage is also a stage to optimize failures that occur by allowing SPCE to perform better. Comparison of substrates used to see the best substrates that can be developed as SPCE substrates as bioelectrochemists were carried out in this study, SPCE as bioelectrokimia sensors have also been sought linear range values and sensitivities so that further development can be carried out
format Final Project
author Arifin Putra Noerrizky, Ivandy
spellingShingle Arifin Putra Noerrizky, Ivandy
DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
author_facet Arifin Putra Noerrizky, Ivandy
author_sort Arifin Putra Noerrizky, Ivandy
title DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
title_short DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
title_full DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
title_fullStr DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
title_full_unstemmed DESIGN, FABRICATION, AND EVALUATION SCREEN- PRINTED ELECTRODE (SPCE) WITH POLYETHYLENE TEREPHTHALATE (PET), POLIVINYL CHLORIDE (PVC) AND PRINTED CIRCUIT BOARD (PCB) SUBSTRATES
title_sort design, fabrication, and evaluation screen- printed electrode (spce) with polyethylene terephthalate (pet), polivinyl chloride (pvc) and printed circuit board (pcb) substrates
url https://digilib.itb.ac.id/gdl/view/69306
_version_ 1822006014740791296