DETERMINATION OF FECAL SLUDGE LOADING FACTOR FROM RESIDENTIAL SEPTIC TANKS THAT ACCESS TO SAFE SANITATION IN CIBINONG SUB-DISTRICT
The pollutant load from domestic wastewater is a significant environmental problem to pay attention to along with the increasing population density. According to the Ministry of Environment and Forestry, 2017, the most significant contributor to BOD pollutants in the Citarum Watershed comes from...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/77641 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | The pollutant load from domestic wastewater is a significant environmental problem to pay
attention to along with the increasing population density. According to the Ministry of
Environment and Forestry, 2017, the most significant contributor to BOD pollutants in the
Citarum Watershed comes from domestic waste (62.16%), as well as the most significant
contributor to BOD pollutants in Bogor Regency is domestic waste (69.21%). It is necessary
to plan the design of a domestic sewage treatment system as an effort to tackle pollution so that
data for calculating the pollutant load factor is needed, which describes the existing conditions
in Cibinong Sub-district, Bogor Regency. Seeing that the most widely used type of domestic
wastewater management system (SPALD) in Bogor Regency is SPALD-S (67.77%) with the
type of SPALD-S septic tank technology, a study was conducted to determine the fecal sludge
pollutant load factor from the septic tank housing that meets access to safe sanitation in
Cibinong Sub-district, Bogor Regency. Based on the results of the study, the range of fecal
sludge emission factor in Cibinong Sub-district with a BOD value of 68.2 g/person/day, COD
of 258.2 g/person/day, TSS of 76.6 g/person/day, and ammonia of 2.8 g/day person/day. The
results of the research on the fecal sludge pollutant load factor from the septic tank in Cibinong
Sub-District are expected to be used as basic data in the preparation of plans for designing
domestic sewage treatment systems, improving domestic sewage treatment systems, calculating
potential pollutant loads and estimating emissions released by septic tanks.
|
---|