EFFICIENCY OF FURNACE HEATING METHODS TUBES FOR DETERMINING CONCENTRATION TRITIUM EN) IN SOIL SAMPLES
Tritium CH) concentration verification method applied on soil sample, tested by heating method using tube furnace. Soil sample was contaminated by tritium in HTO (tritiated water) form then concentration variation between 180-740 Bq of 200 gram soil could be obtained. The contaminated soil was he...