STRUCTURAL AND CONNECTION ANALYSIS AND INSTALLATION METHOD OF TRUSS BRIDGE FOR DN 1000 WATER PIPE IN TANGERANG
Clean water distribution plays an important role in meeting the clean water needs of the community and the private sector, the use of clean water distribution pipes is the choice used by most water supply companies, including the Regional Public Water Supply Company (PERUMDAM). In the water distribu...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/83241 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | Clean water distribution plays an important role in meeting the clean water needs of the community and the private sector, the use of clean water distribution pipes is the choice used by most water supply companies, including the Regional Public Water Supply Company (PERUMDAM). In the water distribution process there are several cases that need to be considered, as in this case is the distribution of water across the river through a pipe bridge. By considering the river span and frame structure of this DN 1000 clean water pipe bridge, it is necessary to analyze the bridge frame structure and the construction of the distribution pipes used in this case.
This study aims to analyze the structure, connections, and installation methods of a truss bridge designed to support the DN 1000 water pipeline in Tangerang. The bridge is 132 meters long with four supports that will support a 1-meter diameter pipe, crossing a river to distribute clean water from its source to areas in need. This study was conducted considering the importance of reliable infrastructure to ensure efficient and sustainable clean water supply.
With the results of the analysis carried out, the safety ratio of the bridge structure is 0.3468, this value is still below 1 so it shows that the structural modeling is safe. Furthermore, the connection used is an angle welding connection and bolts, and the installation method determined is the incremental launching system. |
---|