THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA
The Alam Sutera Public Library Building is intended to create a public space that creates an interactive social environment. The building with a footprint area of approximately 14,000 m2 consists of a basement floor, ground floor, mezzanine floor, 1st floor, and 2nd floor. The plumbing system us...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/84669 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:84669 |
---|---|
spelling |
id-itb.:846692024-08-16T14:09:08ZTHE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA Azka Aulia, Nadhifa Indonesia Final Project Clean Water, Waste Water, Vent, Rain Water, Fire Extinguisher, Public Library Building, Plumbing INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/84669 The Alam Sutera Public Library Building is intended to create a public space that creates an interactive social environment. The building with a footprint area of approximately 14,000 m2 consists of a basement floor, ground floor, mezzanine floor, 1st floor, and 2nd floor. The plumbing system used to provide clean water uses a roof tank with two water sources, namely clean water from PDAM Tirta Kerta Raharja and recycled water. The water requirement for the library building is 33.49 m3 . The volume of the primary clean water bottom tank required is 20 m3 and for the primary clean water top tank, it is 5 m3 , while for the secondary water bottom tank, it is 19 m3 and for the secondary water top tank it is 3 m3 . For wastewater, a separate plumbing system is used to separate dirty water and used water. The generation of wastewater from the PDAM water source is 26.79 m3 /day with the generation of used water of 21.43 m3 /day. The vent uses a loop system. Rainwater will enter the roof drain and be channeled by a vertical rainwater pipe which will then enter the secondary lower tank. The number of sprinklers needed is 702 sprinklers. The planned budget required is Rp. 3,063,579,102 text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The Alam Sutera Public Library Building is intended to create a public space that
creates an interactive social environment. The building with a footprint area of
approximately 14,000 m2
consists of a basement floor, ground floor, mezzanine
floor, 1st floor, and 2nd floor. The plumbing system used to provide clean water
uses a roof tank with two water sources, namely clean water from PDAM Tirta
Kerta Raharja and recycled water. The water requirement for the library building
is 33.49 m3
. The volume of the primary clean water bottom tank required is 20 m3
and for the primary clean water top tank, it is 5 m3
, while for the secondary water
bottom tank, it is 19 m3
and for the secondary water top tank it is 3 m3
. For
wastewater, a separate plumbing system is used to separate dirty water and used
water. The generation of wastewater from the PDAM water source is 26.79 m3
/day
with the generation of used water of 21.43 m3
/day. The vent uses a loop system.
Rainwater will enter the roof drain and be channeled by a vertical rainwater pipe
which will then enter the secondary lower tank. The number of sprinklers needed is
702 sprinklers. The planned budget required is Rp. 3,063,579,102 |
format |
Final Project |
author |
Azka Aulia, Nadhifa |
spellingShingle |
Azka Aulia, Nadhifa THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
author_facet |
Azka Aulia, Nadhifa |
author_sort |
Azka Aulia, Nadhifa |
title |
THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
title_short |
THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
title_full |
THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
title_fullStr |
THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
title_full_unstemmed |
THE DESIGN OF PLUMBING SYSTEMS FOR CLEAN WATER, WASTEWATER, VENT, RAINWATER, AND EXTINGUISHER AT THE PUBLIC LIBRARY BUILDING IN ALAM SUTERA |
title_sort |
design of plumbing systems for clean water, wastewater, vent, rainwater, and extinguisher at the public library building in alam sutera |
url |
https://digilib.itb.ac.id/gdl/view/84669 |
_version_ |
1822282895502344192 |