DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA
Awareness of the importance of emission inventories and emission reduction efforts has increased globally, including in Indonesia. Emission factors (EF) represent the relationship between the amount of pollutants released into the atmosphere and the activities causing their release. Specific emis...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/87023 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:87023 |
---|---|
spelling |
id-itb.:870232025-01-10T07:56:33ZDEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA Utama Prakarsa, Widya Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Theses emission factor, coal-fired power plant, air pollutants, greenhouse gas INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/87023 Awareness of the importance of emission inventories and emission reduction efforts has increased globally, including in Indonesia. Emission factors (EF) represent the relationship between the amount of pollutants released into the atmosphere and the activities causing their release. Specific emission factors, calculated based on particular facilities, are essential for supporting more accurate emission calculations, especially in industrial sectors like coal-fired power plants (CFPPs). This study aims to develop specific emission factors for air pollutants (SO2, NOx, particulates) and greenhouse gas (CO2) based on the characteristics of coal-fired power plants in Indonesia. Air pollutant emission data were obtained from 10 power plant units utilizing continuous emission monitoring systems (CEMS), while coal quality data for calculating CO2 EF were sourced from 153 power plant units. The results show that the SO2 EF for units equipped with emission control devices (controlled) and those without (uncontrolled) are 1,33 g/kg and 1,64 g/kg, respectively. The NOx EF was found to be 1,64 g/kg. For particulates, an EF of 0,09 g/kg was observed in power plants with particulate emission control devices coupled with flue gas desulfurization (FGD), whereas units using only particulate emission control without FGD showed an EF of up to 0,45 g/kg. Analysis indicates that SO2 and particulate emissions are influenced by the type of technology and the age of the power plant, while NOx emissions are more affected by coal combustion conditions. For CO2, the EF values are expressed in three different units: 100,76 ton/TJ, 1,41 ton/MWh, and 1.644,49 g/kg. Statistical tests reveal that age does not significantly affect CO2 EF in any unit, but technology type influences the EF values in ton/MWh and g/kg. Uncertainty analysis yielded uncertainty levels of 5,25%, 3,49%, and 5,74% for SO2, NOx, and particulates, respectively. For CO2, the EF uncertainties in ton/TJ, ton/MWh, and g/kg were 9,28%, 4,85%, and 2,75%, respectively. The relatively higher uncertainty in ton/TJ compared to other countries may be attributed to variations in the measurement and reporting of coal quality, such as net calorific value and carbon content. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan |
spellingShingle |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan Utama Prakarsa, Widya DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
description |
Awareness of the importance of emission inventories and emission reduction efforts
has increased globally, including in Indonesia. Emission factors (EF) represent the
relationship between the amount of pollutants released into the atmosphere and the
activities causing their release. Specific emission factors, calculated based on
particular facilities, are essential for supporting more accurate emission
calculations, especially in industrial sectors like coal-fired power plants (CFPPs).
This study aims to develop specific emission factors for air pollutants (SO2, NOx,
particulates) and greenhouse gas (CO2) based on the characteristics of coal-fired
power plants in Indonesia. Air pollutant emission data were obtained from 10
power plant units utilizing continuous emission monitoring systems (CEMS), while
coal quality data for calculating CO2 EF were sourced from 153 power plant units.
The results show that the SO2 EF for units equipped with emission control devices
(controlled) and those without (uncontrolled) are 1,33 g/kg and 1,64 g/kg,
respectively. The NOx EF was found to be 1,64 g/kg. For particulates, an EF of 0,09
g/kg was observed in power plants with particulate emission control devices
coupled with flue gas desulfurization (FGD), whereas units using only particulate
emission control without FGD showed an EF of up to 0,45 g/kg. Analysis indicates
that SO2 and particulate emissions are influenced by the type of technology and the
age of the power plant, while NOx emissions are more affected by coal combustion
conditions. For CO2, the EF values are expressed in three different units: 100,76
ton/TJ, 1,41 ton/MWh, and 1.644,49 g/kg. Statistical tests reveal that age does not
significantly affect CO2 EF in any unit, but technology type influences the EF values
in ton/MWh and g/kg. Uncertainty analysis yielded uncertainty levels of 5,25%,
3,49%, and 5,74% for SO2, NOx, and particulates, respectively. For CO2, the EF
uncertainties in ton/TJ, ton/MWh, and g/kg were 9,28%, 4,85%, and 2,75%,
respectively. The relatively higher uncertainty in ton/TJ compared to other
countries may be attributed to variations in the measurement and reporting of coal
quality, such as net calorific value and carbon content. |
format |
Theses |
author |
Utama Prakarsa, Widya |
author_facet |
Utama Prakarsa, Widya |
author_sort |
Utama Prakarsa, Widya |
title |
DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
title_short |
DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
title_full |
DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
title_fullStr |
DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
title_full_unstemmed |
DEVELOPMENT OF SPECIFIC EMISSION FACTORS FOR AIR POLLUTANTS AND GREENHOUSE GAS IN COAL-FIRED POWER PLANTS IN INDONESIA |
title_sort |
development of specific emission factors for air pollutants and greenhouse gas in coal-fired power plants in indonesia |
url |
https://digilib.itb.ac.id/gdl/view/87023 |
_version_ |
1822999775238160384 |