EXPERIMENTAL STUDY ON THE EFFECT OF ADDITIVE COMPOSITION ON SLAGGING BEHAVIOR IN A TANGENTIAL BOILER AT COAL POWER PLANT TANJUNG JATI B UNIT 3
PLTU Tanjung Jati B Unit 3 with a tangential firing boiler, currently consumes coal with a calorific value below its design specification (5618 kcal/kg compared to the specified 5900 kcal/kg). This condition leads to rapid and massive slagging formation, resulting in operational losses of 707,711 MW...