EXPERIMENTAL STUDY ON THE EFFECT OF ADDITIVE COMPOSITION ON SLAGGING BEHAVIOR IN A TANGENTIAL BOILER AT COAL POWER PLANT TANJUNG JATI B UNIT 3
PLTU Tanjung Jati B Unit 3 with a tangential firing boiler, currently consumes coal with a calorific value below its design specification (5618 kcal/kg compared to the specified 5900 kcal/kg). This condition leads to rapid and massive slagging formation, resulting in operational losses of 707,711 MW...
Saved in:
Main Author: | Reza Maulana Fasya, Teuku |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/87149 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Similar Items
-
EXPERIMENTAL STUDY ON THE IMPACT OF ADDITIVE COMPOSITION ON SLAGGING IN A FRONT-REAR BOILER PLTU TANJUNG JATI B UNIT 2
by: Fauzi Effendi, Eddy -
EFFECT OF EXCESS AIR ON COAL COMBUSTION OF A 265 MW TANGENTIAL FIRED BOILER
by: Ananto Pramudyo, Dwi -
OPTIMALISASI KINERJA SOOT BLOWER PADA BOILER PLTU TANJUNG JATI B
by: , EGI NUGROHO, et al.
Published: (2013) -
OPERASI, PERAWATAN DAN EFISIENSI BOILER
Pada PT PLN Pembangkitan Tanjung Jati B
by: , LISTIANTO, et al.
Published: (2013) -
Study the phenomenon of slagging and fouling Low Rank Coal (LRC) at boiler Unit 1-4 Suralaya Steam Power Plant by Computational Fluid Dynamic (CFD) modeling
by: Hanafi Nur Rifa'i, Moch