New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration pl...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/9671 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:9671 |
---|---|
spelling |
id-itb.:96712017-09-27T11:42:33Z#TITLE_ALTERNATIVE# LESMANA (NIM 10503016), YOGA Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/9671 New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration plot in the concentration range of 0.01 - 8 mM showing good linearity with detection limit of 3.43 x 10(-6) M. Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy drink samples showing good results. On the other hand, analysis accuracy of multivitamine sample is low. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration plot in the concentration range of 0.01 - 8 mM showing good linearity with detection limit of 3.43 x 10(-6) M. Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy drink samples showing good results. On the other hand, analysis accuracy of multivitamine sample is low. |
format |
Final Project |
author |
LESMANA (NIM 10503016), YOGA |
spellingShingle |
LESMANA (NIM 10503016), YOGA #TITLE_ALTERNATIVE# |
author_facet |
LESMANA (NIM 10503016), YOGA |
author_sort |
LESMANA (NIM 10503016), YOGA |
title |
#TITLE_ALTERNATIVE# |
title_short |
#TITLE_ALTERNATIVE# |
title_full |
#TITLE_ALTERNATIVE# |
title_fullStr |
#TITLE_ALTERNATIVE# |
title_full_unstemmed |
#TITLE_ALTERNATIVE# |
title_sort |
#title_alternative# |
url |
https://digilib.itb.ac.id/gdl/view/9671 |
_version_ |
1820664762218840064 |