New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration pl...

Full description

Saved in:
Bibliographic Details
Main Author: LESMANA (NIM 10503016), YOGA
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/9671
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:9671
spelling id-itb.:96712017-09-27T11:42:33Z#TITLE_ALTERNATIVE# LESMANA (NIM 10503016), YOGA Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/9671 New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration plot in the concentration range of 0.01 - 8 mM showing good linearity with detection limit of 3.43 x 10(-6) M. Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy drink samples showing good results. On the other hand, analysis accuracy of multivitamine sample is low. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I(-). The I(-) ion which is formed then oxidized on platinum electrode. The calibration plot in the concentration range of 0.01 - 8 mM showing good linearity with detection limit of 3.43 x 10(-6) M. Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy drink samples showing good results. On the other hand, analysis accuracy of multivitamine sample is low.
format Final Project
author LESMANA (NIM 10503016), YOGA
spellingShingle LESMANA (NIM 10503016), YOGA
#TITLE_ALTERNATIVE#
author_facet LESMANA (NIM 10503016), YOGA
author_sort LESMANA (NIM 10503016), YOGA
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/9671
_version_ 1820664762218840064