VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN

Vitamin D3 is a fat-soluble vitamin that is available with other vitamins in multivitamin tablet. As a health supplement, the amount of vitamin D3 in multivitamin tablet is 400 IU or equivalent to 10μg in each tablet. Due to the low level of vitamin D3 contained in this complex sample matrix, a...

Full description

Saved in:
Bibliographic Details
Main Author: EVI NUR’AIN MURANDANI, 051511133170
Format: Theses and Dissertations NonPeerReviewed
Language:English
English
English
Indonesian
Published: 2019
Subjects:
Online Access:http://repository.unair.ac.id/90863/1/FF.KF.17-19%20Mur%20v%20abstrak.pdf
http://repository.unair.ac.id/90863/2/FF.KF.17-19%20Mur%20v%20daftar%20isi.pdf
http://repository.unair.ac.id/90863/3/FF.KF.17-19%20Mur%20v%20daftar%20pustaka.pdf
http://repository.unair.ac.id/90863/4/FF.KF.17-19%20Mur%20v.pdf
http://repository.unair.ac.id/90863/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universitas Airlangga
Language: English
English
English
Indonesian
id id-langga.90863
record_format dspace
spelling id-langga.908632019-11-14T02:48:56Z http://repository.unair.ac.id/90863/ VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN EVI NUR’AIN MURANDANI, 051511133170 RS Pharmacy and materia medica Vitamin D3 is a fat-soluble vitamin that is available with other vitamins in multivitamin tablet. As a health supplement, the amount of vitamin D3 in multivitamin tablet is 400 IU or equivalent to 10μg in each tablet. Due to the low level of vitamin D3 contained in this complex sample matrix, a specific and sensitive method is needed to ensure the product quality, safety and efficacy. Therefore, Gas Chromatography – Mass Spectrometry is used in this study, because of its high sensitivity, high resolution, andspecifically detection ofthe analytesat low concentration in samples. The objective of the present study was to validate the GC-MS methods in terms of specificity, linearity, range, accuracy and precision. The proposed method was carried out without derivatization. The optimum condition was reached by oven temperature program with initial temperature of 150°C for 2 minutes, then increased by 25°C/minute to the final temperature of 280°C for 10 minutes. The time needed for running is about 17.20 minutes. From the result of the method validation, the retention time of vitamin D3 was 8 minutes with resolution of 2.86. The method showed a linear response (r=0.997) with Vxo of 3.54%. The average of percent recovery of the sample was 98.71% with relative standard deviation of 2.57%. Detection and quantitation limits were found to be 0.61 ppm and 1.85 ppm, respectively. 2019 Thesis NonPeerReviewed text en http://repository.unair.ac.id/90863/1/FF.KF.17-19%20Mur%20v%20abstrak.pdf text en http://repository.unair.ac.id/90863/2/FF.KF.17-19%20Mur%20v%20daftar%20isi.pdf text en http://repository.unair.ac.id/90863/3/FF.KF.17-19%20Mur%20v%20daftar%20pustaka.pdf text id http://repository.unair.ac.id/90863/4/FF.KF.17-19%20Mur%20v.pdf EVI NUR’AIN MURANDANI, 051511133170 (2019) VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN. Skripsi thesis, Universitas Airlangga. Http://lib.Unair.ac.id
institution Universitas Airlangga
building Universitas Airlangga Library
country Indonesia
collection UNAIR Repository
language English
English
English
Indonesian
topic RS Pharmacy and materia medica
spellingShingle RS Pharmacy and materia medica
EVI NUR’AIN MURANDANI, 051511133170
VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
description Vitamin D3 is a fat-soluble vitamin that is available with other vitamins in multivitamin tablet. As a health supplement, the amount of vitamin D3 in multivitamin tablet is 400 IU or equivalent to 10μg in each tablet. Due to the low level of vitamin D3 contained in this complex sample matrix, a specific and sensitive method is needed to ensure the product quality, safety and efficacy. Therefore, Gas Chromatography – Mass Spectrometry is used in this study, because of its high sensitivity, high resolution, andspecifically detection ofthe analytesat low concentration in samples. The objective of the present study was to validate the GC-MS methods in terms of specificity, linearity, range, accuracy and precision. The proposed method was carried out without derivatization. The optimum condition was reached by oven temperature program with initial temperature of 150°C for 2 minutes, then increased by 25°C/minute to the final temperature of 280°C for 10 minutes. The time needed for running is about 17.20 minutes. From the result of the method validation, the retention time of vitamin D3 was 8 minutes with resolution of 2.86. The method showed a linear response (r=0.997) with Vxo of 3.54%. The average of percent recovery of the sample was 98.71% with relative standard deviation of 2.57%. Detection and quantitation limits were found to be 0.61 ppm and 1.85 ppm, respectively.
format Theses and Dissertations
NonPeerReviewed
author EVI NUR’AIN MURANDANI, 051511133170
author_facet EVI NUR’AIN MURANDANI, 051511133170
author_sort EVI NUR’AIN MURANDANI, 051511133170
title VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
title_short VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
title_full VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
title_fullStr VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
title_full_unstemmed VALIDASI METODE KROMATOGRAFI GAS DETEKTOR SPEKTROMETRI MASSA UNTUK PENETAPAN KADAR VITAMIN D3 DALAM SEDIAAN TABLET MULTIVITAMIN
title_sort validasi metode kromatografi gas detektor spektrometri massa untuk penetapan kadar vitamin d3 dalam sediaan tablet multivitamin
publishDate 2019
url http://repository.unair.ac.id/90863/1/FF.KF.17-19%20Mur%20v%20abstrak.pdf
http://repository.unair.ac.id/90863/2/FF.KF.17-19%20Mur%20v%20daftar%20isi.pdf
http://repository.unair.ac.id/90863/3/FF.KF.17-19%20Mur%20v%20daftar%20pustaka.pdf
http://repository.unair.ac.id/90863/4/FF.KF.17-19%20Mur%20v.pdf
http://repository.unair.ac.id/90863/
_version_ 1681152898210201600