Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy

A new, rapid, and direct method was developed for the determination of moisture content in biodiesel produced from various types of oils using Fourier transform infrared (FTIR) spectroscopy with an attenuated total reflectance (ATR) element. Samples of biodiesels used in this study were produced usi...

Full description

Saved in:
Bibliographic Details
Main Authors: Mirghani, Mohamed Elwathig Saeed, Kabbashi, Nasreldin A., Alam, Md Zahangir, Qudsieh, Isam Y., Al-Khatib, Ma'an Fahmi Rashid
Format: Article
Language:English
Published: Springer Berlin 2011
Subjects:
Online Access:http://irep.iium.edu.my/2645/4/Rapid_Method_for_the_Determination_of_Moisture_Content.pdf
http://irep.iium.edu.my/2645/
http://www.springerlink.com/content/g40073118w5k2786/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Islam Antarabangsa Malaysia
Language: English
id my.iium.irep.2645
record_format dspace
spelling my.iium.irep.26452024-05-02T08:19:02Z http://irep.iium.edu.my/2645/ Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy Mirghani, Mohamed Elwathig Saeed Kabbashi, Nasreldin A. Alam, Md Zahangir Qudsieh, Isam Y. Al-Khatib, Ma'an Fahmi Rashid T Technology (General) TP Chemical technology A new, rapid, and direct method was developed for the determination of moisture content in biodiesel produced from various types of oils using Fourier transform infrared (FTIR) spectroscopy with an attenuated total reflectance (ATR) element. Samples of biodiesels used in this study were produced using sludge palm oil (SPO). The calibration set was prepared by spiking double-distilled water into dried biodiesel samples in ratios (w/w) between 0 and 10% moisture. Absorbance values from the wavelength regions 3,700–3,075 and 1,700–1,500 cm-1, and the partial least square (PLS) regression method were used to derive a FTIR spectroscopic calibration model for moisture content in biodiesel samples. The coefficient of determinations (R2) for the models was computed by comparing the results obtained from FTIR spectroscopy against the values of the moisture concentrations (%) determined using the American Oil Chemists’ Society (AOCS) oven method Ca 2d-25. Same comparison was done using International Union of Pure and Applied Chemistry (IUPAC) distillation method 2.602. R2 was 0.9793 and 0.9700 using AOCS and IUPAC methods, respectively. The standard error (SE) of calibration was 1.84. The calibration model was cross validated within the same set of samples, and the standard deviation (SD) of the difference for repeatability (SDDr) and accuracy (SDDa) of the FTIR method was determined. With its speed and ease of data manipulation, FTIR spectroscopy is a useful alternative method to other methods for rapid and routine determination of moisture content in biodiesel for quality control. Springer Berlin 2011-06-10 Article PeerReviewed application/pdf en http://irep.iium.edu.my/2645/4/Rapid_Method_for_the_Determination_of_Moisture_Content.pdf Mirghani, Mohamed Elwathig Saeed and Kabbashi, Nasreldin A. and Alam, Md Zahangir and Qudsieh, Isam Y. and Al-Khatib, Ma'an Fahmi Rashid (2011) Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy. Journal Of The American Oil Chemists' Society. ISSN 0003-021X http://www.springerlink.com/content/g40073118w5k2786/ DOI 10.1007/s11746-011-1866-0
institution Universiti Islam Antarabangsa Malaysia
building IIUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider International Islamic University Malaysia
content_source IIUM Repository (IREP)
url_provider http://irep.iium.edu.my/
language English
topic T Technology (General)
TP Chemical technology
spellingShingle T Technology (General)
TP Chemical technology
Mirghani, Mohamed Elwathig Saeed
Kabbashi, Nasreldin A.
Alam, Md Zahangir
Qudsieh, Isam Y.
Al-Khatib, Ma'an Fahmi Rashid
Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
description A new, rapid, and direct method was developed for the determination of moisture content in biodiesel produced from various types of oils using Fourier transform infrared (FTIR) spectroscopy with an attenuated total reflectance (ATR) element. Samples of biodiesels used in this study were produced using sludge palm oil (SPO). The calibration set was prepared by spiking double-distilled water into dried biodiesel samples in ratios (w/w) between 0 and 10% moisture. Absorbance values from the wavelength regions 3,700–3,075 and 1,700–1,500 cm-1, and the partial least square (PLS) regression method were used to derive a FTIR spectroscopic calibration model for moisture content in biodiesel samples. The coefficient of determinations (R2) for the models was computed by comparing the results obtained from FTIR spectroscopy against the values of the moisture concentrations (%) determined using the American Oil Chemists’ Society (AOCS) oven method Ca 2d-25. Same comparison was done using International Union of Pure and Applied Chemistry (IUPAC) distillation method 2.602. R2 was 0.9793 and 0.9700 using AOCS and IUPAC methods, respectively. The standard error (SE) of calibration was 1.84. The calibration model was cross validated within the same set of samples, and the standard deviation (SD) of the difference for repeatability (SDDr) and accuracy (SDDa) of the FTIR method was determined. With its speed and ease of data manipulation, FTIR spectroscopy is a useful alternative method to other methods for rapid and routine determination of moisture content in biodiesel for quality control.
format Article
author Mirghani, Mohamed Elwathig Saeed
Kabbashi, Nasreldin A.
Alam, Md Zahangir
Qudsieh, Isam Y.
Al-Khatib, Ma'an Fahmi Rashid
author_facet Mirghani, Mohamed Elwathig Saeed
Kabbashi, Nasreldin A.
Alam, Md Zahangir
Qudsieh, Isam Y.
Al-Khatib, Ma'an Fahmi Rashid
author_sort Mirghani, Mohamed Elwathig Saeed
title Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
title_short Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
title_full Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
title_fullStr Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
title_full_unstemmed Rapid method for the determination of moisture content in biodiesel using FTIR spectroscopy
title_sort rapid method for the determination of moisture content in biodiesel using ftir spectroscopy
publisher Springer Berlin
publishDate 2011
url http://irep.iium.edu.my/2645/4/Rapid_Method_for_the_Determination_of_Moisture_Content.pdf
http://irep.iium.edu.my/2645/
http://www.springerlink.com/content/g40073118w5k2786/
_version_ 1800081730149810176