Design and optimization of a micro capacitive pressure sensor
The shape of Micropressure sensors has influence on their accuracy. In this paper, a rectangular membrane type Micropressure sensor had been modeled using finite element package and shape optimization in order to design a more accurate flexible membrane. The results show that adding a slim wall, to...
محفوظ في:
المؤلفون الرئيسيون: | , , |
---|---|
التنسيق: | Conference or Workshop Item |
اللغة: | English English |
منشور في: |
2013
|
الموضوعات: | |
الوصول للمادة أونلاين: | http://irep.iium.edu.my/32171/1/Paper_30177_-_Camera_ready.pdf http://irep.iium.edu.my/32171/4/Proceeding-CoverPage.pdf http://irep.iium.edu.my/32171/ |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
المؤسسة: | Universiti Islam Antarabangsa Malaysia |
اللغة: | English English |
الملخص: | The shape of Micropressure sensors has influence on their accuracy. In this paper, a rectangular membrane type Micropressure sensor had been modeled using finite element package and shape optimization in order to design a more accurate flexible membrane. The results show that adding a slim wall, to protect the pressure sensor and system during pressure shocks, has a negligible effect on the membrane flexibility. Moreover, the simulation results show that the sensor exhibits a linear response with wide range of pressure from 0.01 MPa to 70 MPa. Furthermore, the simulation results yielded that the load-deflection responses could be enhanced using a spacer. |
---|