Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples
Poly(methyl methacrylate-vinyl imidazole bromide) (poly-MMA-IL)-grafted magnetic nanoparticles were successfully developed and applied in the micro-magnetic solid phase extraction (mu-MSPE) for 16 types of polycyclic aromatic hydrocarbons (PAHs) from tea, fried food, and grilled food samples via gas...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Taylor & Francis
2024
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/47025/ https://doi.org/10.2174/10.1080/19440049.2024.2326426 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Malaya |
id |
my.um.eprints.47025 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.470252025-01-07T08:45:20Z http://eprints.um.edu.my/47025/ Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples Yunus, Faizah Muhammad Alias, Yatimah Yahya, Noorfatimah Zain, Nur Nadhirah Mohamad Raoov, Muggundha Q Science (General) QD Chemistry Poly(methyl methacrylate-vinyl imidazole bromide) (poly-MMA-IL)-grafted magnetic nanoparticles were successfully developed and applied in the micro-magnetic solid phase extraction (mu-MSPE) for 16 types of polycyclic aromatic hydrocarbons (PAHs) from tea, fried food, and grilled food samples via gas chromatography flame ionization detector (GC-FID). One variable at a time (OVAT) and response surface methodology (RSM) were used for efficient optimization. The validation method showed a good coefficient of determination (R-2) ranging from 0.9901 to 0.9982 (n = 3) with linearity of 0.2 mu g L-1-500 mu g L-1. Detection and quantification limits were 0.06 mu g L-1-0.32 mu g L-1 and 0.18 mu g L-1-0.97 mu g L-1. Additionally, satisfactory reproducibility was attained with intra-day and inter-day precisions having RSD ranges of 3.6%-11.1%. The spiked recovery value of 16 PAHs in fried food, grilled food and tea samples obtained from the night market in Malaysia ranged from 80%-12%, respectively. Taylor & Francis 2024-05 Article PeerReviewed Yunus, Faizah Muhammad and Alias, Yatimah and Yahya, Noorfatimah and Zain, Nur Nadhirah Mohamad and Raoov, Muggundha (2024) Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples. Food Additives and Contaminants Part A-Chemistry Analysis Control Exposure & Risk Assessment, 41 (5). pp. 495-512. ISSN 1944-0049, DOI https://doi.org/10.1080/19440049.2024.2326426 <https://doi.org/10.1080/19440049.2024.2326426>. https://doi.org/10.2174/10.1080/19440049.2024.2326426 10.1080/19440049.2024.2326426 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
Q Science (General) QD Chemistry |
spellingShingle |
Q Science (General) QD Chemistry Yunus, Faizah Muhammad Alias, Yatimah Yahya, Noorfatimah Zain, Nur Nadhirah Mohamad Raoov, Muggundha Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
description |
Poly(methyl methacrylate-vinyl imidazole bromide) (poly-MMA-IL)-grafted magnetic nanoparticles were successfully developed and applied in the micro-magnetic solid phase extraction (mu-MSPE) for 16 types of polycyclic aromatic hydrocarbons (PAHs) from tea, fried food, and grilled food samples via gas chromatography flame ionization detector (GC-FID). One variable at a time (OVAT) and response surface methodology (RSM) were used for efficient optimization. The validation method showed a good coefficient of determination (R-2) ranging from 0.9901 to 0.9982 (n = 3) with linearity of 0.2 mu g L-1-500 mu g L-1. Detection and quantification limits were 0.06 mu g L-1-0.32 mu g L-1 and 0.18 mu g L-1-0.97 mu g L-1. Additionally, satisfactory reproducibility was attained with intra-day and inter-day precisions having RSD ranges of 3.6%-11.1%. The spiked recovery value of 16 PAHs in fried food, grilled food and tea samples obtained from the night market in Malaysia ranged from 80%-12%, respectively. |
format |
Article |
author |
Yunus, Faizah Muhammad Alias, Yatimah Yahya, Noorfatimah Zain, Nur Nadhirah Mohamad Raoov, Muggundha |
author_facet |
Yunus, Faizah Muhammad Alias, Yatimah Yahya, Noorfatimah Zain, Nur Nadhirah Mohamad Raoov, Muggundha |
author_sort |
Yunus, Faizah Muhammad |
title |
Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
title_short |
Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
title_full |
Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
title_fullStr |
Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
title_full_unstemmed |
Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
title_sort |
poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples |
publisher |
Taylor & Francis |
publishDate |
2024 |
url |
http://eprints.um.edu.my/47025/ https://doi.org/10.2174/10.1080/19440049.2024.2326426 |
_version_ |
1821105755710816256 |