Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation

Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error...

Full description

Saved in:
Bibliographic Details
Main Authors: Nurul Nadia, Mohammad, Mohd Hezri, Marzaki, Ramli, Adnan, Mohd Hezri, Fazalul Rahiman, Saiful Nizam, Tajuddin
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28970/1/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation_FULL.pdf
http://umpir.ump.edu.my/id/eprint/28970/2/Evaluation%20of%20energy%20consumption%20in%20small-scale%20agarwood%20distillation%20.pdf
http://umpir.ump.edu.my/id/eprint/28970/
https://doi.org/10.1109/CSPA.2017.8064965
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Malaysia Pahang
Language: English
English
Description
Summary:Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load to enhance the performance of the system. In this study, a setpoint was set to 80°C and the comparative performance of PID controller with several tuning rules was evaluate and analyse via simulation. The analysis of the performance was depend on settling time, percentage of overshoot and rise time. Moreover, in this study, the average amount of control signal have been evaluated based on several tuning rules by using an integral control signal. The simulation result shows the ISE-Load that completed with minimum percentage of overshoot could result in best temperature control for hydro distillation process. However, in term of energy consumption, PID ZN gives lower energy usage.