Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein

A simple and rapid method for the quantitative determination of free fatty acid (FFA) contents in palm olein by Fourier transform infrared (FTIR) transmission spectroscope is described. A set of palm olein samples is used as the calibration set. This set was prepared by spiking increasing amounts of...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Man, Y.B., Setiowaty, G.
Format: Article
Language:English
Published: Elsevier Science 1999
Online Access:http://psasir.upm.edu.my/id/eprint/114386/1/114386.pdf
http://psasir.upm.edu.my/id/eprint/114386/
https://linkinghub.elsevier.com/retrieve/pii/S0308814698002544
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.114386
record_format eprints
spelling my.upm.eprints.1143862025-02-05T03:38:19Z http://psasir.upm.edu.my/id/eprint/114386/ Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein Che Man, Y.B. Setiowaty, G. A simple and rapid method for the quantitative determination of free fatty acid (FFA) contents in palm olein by Fourier transform infrared (FTIR) transmission spectroscope is described. A set of palm olein samples is used as the calibration set. This set was prepared by spiking increasing amounts of oleic acid into a series of palm oleins that covers a wide range of FFA (0.08-1.04%). A partial least squares (PLS) calibration model for the prediction of FFA contents was developed, based on the spectral range 1728-1662 cm-1. This model was tested by cross-validation steps to minimize standard error of the model. The coefficient of determination (R2) and standard error were 0.997 and 0.017% of a FFA unit. Accuracy of the method was determined by comparing the FFA of a series of oleic acid-spiked palm oleins predicted by a PLS model to values obtained by the AOCS titration method. For accuracy, the difference between the mean FFA determined by the chemical method and the mean FFA determined by the FTIR method (MD(a)) gave FFA contents of a value of 0.00016, with the FTIR method giving a higher prediction of palm olein than the AOCS method. For reproducibility, the mean differences between duplicates (MD(r)) of the chemical and FTIR methods were close to zero (-0.0064 and -0.0046, respectively). The implementation of such a method as a quality control tool would eliminate the use and disposal of hazardous solvents required by the chemical method, and drastically reduce analysis time to less than 2 min/sample. Elsevier Science 1999 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/114386/1/114386.pdf Che Man, Y.B. and Setiowaty, G. (1999) Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein. Food Chemistry, 66 (1). pp. 109-114. ISSN 0308-8146; eISSN: 0308-8146 https://linkinghub.elsevier.com/retrieve/pii/S0308814698002544 10.1016/S0308-8146(98)00254-4
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description A simple and rapid method for the quantitative determination of free fatty acid (FFA) contents in palm olein by Fourier transform infrared (FTIR) transmission spectroscope is described. A set of palm olein samples is used as the calibration set. This set was prepared by spiking increasing amounts of oleic acid into a series of palm oleins that covers a wide range of FFA (0.08-1.04%). A partial least squares (PLS) calibration model for the prediction of FFA contents was developed, based on the spectral range 1728-1662 cm-1. This model was tested by cross-validation steps to minimize standard error of the model. The coefficient of determination (R2) and standard error were 0.997 and 0.017% of a FFA unit. Accuracy of the method was determined by comparing the FFA of a series of oleic acid-spiked palm oleins predicted by a PLS model to values obtained by the AOCS titration method. For accuracy, the difference between the mean FFA determined by the chemical method and the mean FFA determined by the FTIR method (MD(a)) gave FFA contents of a value of 0.00016, with the FTIR method giving a higher prediction of palm olein than the AOCS method. For reproducibility, the mean differences between duplicates (MD(r)) of the chemical and FTIR methods were close to zero (-0.0064 and -0.0046, respectively). The implementation of such a method as a quality control tool would eliminate the use and disposal of hazardous solvents required by the chemical method, and drastically reduce analysis time to less than 2 min/sample.
format Article
author Che Man, Y.B.
Setiowaty, G.
spellingShingle Che Man, Y.B.
Setiowaty, G.
Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
author_facet Che Man, Y.B.
Setiowaty, G.
author_sort Che Man, Y.B.
title Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
title_short Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
title_full Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
title_fullStr Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
title_full_unstemmed Application of Fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
title_sort application of fourier transform infrared spectroscopy to determine free fatty acid contents in palm olein
publisher Elsevier Science
publishDate 1999
url http://psasir.upm.edu.my/id/eprint/114386/1/114386.pdf
http://psasir.upm.edu.my/id/eprint/114386/
https://linkinghub.elsevier.com/retrieve/pii/S0308814698002544
_version_ 1823276358006996992