Adverse impact of STATCOM on the performance of distance relay

FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is pr...

Full description

Saved in:
Bibliographic Details
Main Authors: Aker, Elhadi Emhemad, Othman, Mohammad Lutfi, Aris, Ishak, Abdul Wahab, Noor Izzri, Hizam, Hashim, Emmanuel, Osaji
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2017
Online Access:http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf
http://psasir.upm.edu.my/id/eprint/60785/
https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.60785
record_format eprints
spelling my.upm.eprints.607852019-04-29T06:16:54Z http://psasir.upm.edu.my/id/eprint/60785/ Adverse impact of STATCOM on the performance of distance relay Aker, Elhadi Emhemad Othman, Mohammad Lutfi Aris, Ishak Abdul Wahab, Noor Izzri Hizam, Hashim Emmanuel, Osaji FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is presented. The STATCOM’s impact on the operation of the relay is assessed with the effects on the relay misoperation in the third zone of protection coverage, during fault conditions, in four different locations.The wrong measured fault impedance by relay resulted to misoperation in zone 3 (under reach phenomena). The simulation result indicates a slight increase in the measured impedance of 1.33 Ω over the actually expected impedance setting (72.02 Ω) of the relay at 220 km protection coverage of zone 3 along the TL. This variation is about 4 km distance outside the expected distance protection coverage for fault in zone 3 as proven. Institute of Advanced Engineering and Science 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf Aker, Elhadi Emhemad and Othman, Mohammad Lutfi and Aris, Ishak and Abdul Wahab, Noor Izzri and Hizam, Hashim and Emmanuel, Osaji (2017) Adverse impact of STATCOM on the performance of distance relay. Indonesian Journal of Electrical Engineering and Computer Science, 6 (3). 528 - 536. ISSN 2502-4760; ESSN: 2502-4752 https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf 10.11591/ijeecs.v6.i3.pp528-536
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is presented. The STATCOM’s impact on the operation of the relay is assessed with the effects on the relay misoperation in the third zone of protection coverage, during fault conditions, in four different locations.The wrong measured fault impedance by relay resulted to misoperation in zone 3 (under reach phenomena). The simulation result indicates a slight increase in the measured impedance of 1.33 Ω over the actually expected impedance setting (72.02 Ω) of the relay at 220 km protection coverage of zone 3 along the TL. This variation is about 4 km distance outside the expected distance protection coverage for fault in zone 3 as proven.
format Article
author Aker, Elhadi Emhemad
Othman, Mohammad Lutfi
Aris, Ishak
Abdul Wahab, Noor Izzri
Hizam, Hashim
Emmanuel, Osaji
spellingShingle Aker, Elhadi Emhemad
Othman, Mohammad Lutfi
Aris, Ishak
Abdul Wahab, Noor Izzri
Hizam, Hashim
Emmanuel, Osaji
Adverse impact of STATCOM on the performance of distance relay
author_facet Aker, Elhadi Emhemad
Othman, Mohammad Lutfi
Aris, Ishak
Abdul Wahab, Noor Izzri
Hizam, Hashim
Emmanuel, Osaji
author_sort Aker, Elhadi Emhemad
title Adverse impact of STATCOM on the performance of distance relay
title_short Adverse impact of STATCOM on the performance of distance relay
title_full Adverse impact of STATCOM on the performance of distance relay
title_fullStr Adverse impact of STATCOM on the performance of distance relay
title_full_unstemmed Adverse impact of STATCOM on the performance of distance relay
title_sort adverse impact of statcom on the performance of distance relay
publisher Institute of Advanced Engineering and Science
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf
http://psasir.upm.edu.my/id/eprint/60785/
https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf
_version_ 1643837438658871296