Adverse impact of STATCOM on the performance of distance relay
FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is pr...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2017
|
Online Access: | http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf http://psasir.upm.edu.my/id/eprint/60785/ https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.60785 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.607852019-04-29T06:16:54Z http://psasir.upm.edu.my/id/eprint/60785/ Adverse impact of STATCOM on the performance of distance relay Aker, Elhadi Emhemad Othman, Mohammad Lutfi Aris, Ishak Abdul Wahab, Noor Izzri Hizam, Hashim Emmanuel, Osaji FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is presented. The STATCOM’s impact on the operation of the relay is assessed with the effects on the relay misoperation in the third zone of protection coverage, during fault conditions, in four different locations.The wrong measured fault impedance by relay resulted to misoperation in zone 3 (under reach phenomena). The simulation result indicates a slight increase in the measured impedance of 1.33 Ω over the actually expected impedance setting (72.02 Ω) of the relay at 220 km protection coverage of zone 3 along the TL. This variation is about 4 km distance outside the expected distance protection coverage for fault in zone 3 as proven. Institute of Advanced Engineering and Science 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf Aker, Elhadi Emhemad and Othman, Mohammad Lutfi and Aris, Ishak and Abdul Wahab, Noor Izzri and Hizam, Hashim and Emmanuel, Osaji (2017) Adverse impact of STATCOM on the performance of distance relay. Indonesian Journal of Electrical Engineering and Computer Science, 6 (3). 528 - 536. ISSN 2502-4760; ESSN: 2502-4752 https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf 10.11591/ijeecs.v6.i3.pp528-536 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
FACTS devices like the Static Synchronous Compensator (STATCOM), are mostly used to enhance the maximum power transfer capability of the transmission Line (TL) system. AMatlab simulation model of Distance Relay protection ofTL, with connected STATCOM at the mid-point for optimum power transfer is presented. The STATCOM’s impact on the operation of the relay is assessed with the effects on the relay misoperation in the third zone of protection coverage, during fault conditions, in four different locations.The wrong measured fault impedance by relay resulted to misoperation in zone 3 (under reach phenomena). The simulation result indicates a slight increase in the measured impedance of 1.33 Ω over the actually expected impedance setting (72.02 Ω) of the relay at 220 km protection coverage of zone 3 along the TL. This variation is about 4 km distance outside the expected distance protection coverage for fault in zone 3 as proven. |
format |
Article |
author |
Aker, Elhadi Emhemad Othman, Mohammad Lutfi Aris, Ishak Abdul Wahab, Noor Izzri Hizam, Hashim Emmanuel, Osaji |
spellingShingle |
Aker, Elhadi Emhemad Othman, Mohammad Lutfi Aris, Ishak Abdul Wahab, Noor Izzri Hizam, Hashim Emmanuel, Osaji Adverse impact of STATCOM on the performance of distance relay |
author_facet |
Aker, Elhadi Emhemad Othman, Mohammad Lutfi Aris, Ishak Abdul Wahab, Noor Izzri Hizam, Hashim Emmanuel, Osaji |
author_sort |
Aker, Elhadi Emhemad |
title |
Adverse impact of STATCOM on the performance of distance relay |
title_short |
Adverse impact of STATCOM on the performance of distance relay |
title_full |
Adverse impact of STATCOM on the performance of distance relay |
title_fullStr |
Adverse impact of STATCOM on the performance of distance relay |
title_full_unstemmed |
Adverse impact of STATCOM on the performance of distance relay |
title_sort |
adverse impact of statcom on the performance of distance relay |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2017 |
url |
http://psasir.upm.edu.my/id/eprint/60785/1/Adverse%20impact%20of%20STATCOM%20on%20the%20performance%20of%20distance%20relay.pdf http://psasir.upm.edu.my/id/eprint/60785/ https://www.researchgate.net/profile/Mohammad_Lutfi_Othman/publication/317659857_Adverse_impact_of_STATCOM_on_the_performance_of_distance_relay/links/59477b5eaca2722db4a617c8/Adverse-impact-of-STATCOM-on-the-performance-of-distance-relay.pdf |
_version_ |
1643837438658871296 |