Compression resistance of short cold-formed lipped C channel section with web stiffening

This paper presents the compression resistance of the short cold-formed lipped C channel section after being strengthened with a web stiffener. The failure modes of short cold-formed lipped C channel section with web stiffening under axial compression load are also investigated in this research. Fur...

Full description

Saved in:
Bibliographic Details
Main Authors: Goh, Yong Sheng, Tan, Hean Seong, Shek, Poi Ngian, Mohamad Zin, Rosli, Abd. Latif, Siti Asma
Format: Conference or Workshop Item
Published: 2023
Subjects:
Online Access:http://eprints.utm.my/107894/
http://dx.doi.org/10.1007/978-981-19-8024-4_35
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.107894
record_format eprints
spelling my.utm.1078942024-10-08T06:55:53Z http://eprints.utm.my/107894/ Compression resistance of short cold-formed lipped C channel section with web stiffening Goh, Yong Sheng Tan, Hean Seong Shek, Poi Ngian Mohamad Zin, Rosli Abd. Latif, Siti Asma TA Engineering (General). Civil engineering (General) This paper presents the compression resistance of the short cold-formed lipped C channel section after being strengthened with a web stiffener. The failure modes of short cold-formed lipped C channel section with web stiffening under axial compression load are also investigated in this research. Furthermore, the comparison has been made between the short column with and without stiffener in terms of ultimate load capacity and failure mode. The web stiffener which is a steel plate of 100 mm in width and 6.2 mm in thickness is connected to the web of the specimen using bolted and welded connection. For bolted connections, three different spacing between bolt is proposed to determine the effect of the spacing toward the compressive strength of the specimen. Two failure modes, local buckling and distortional buckling, are observed during the experiment. From the comparison, the compression resistance of column with web stiffener has increased significantly. The increment in strength is in the range from 0.25 to 1.00. For the column with web stiffening, compression resistance for the different connection methods is compared. The welding connection reached the highest ultimate load capacity. The theoretical prediction using BS EN 1993: 1-3 [8] shows good agreement with the experimental result. 2023 Conference or Workshop Item PeerReviewed Goh, Yong Sheng and Tan, Hean Seong and Shek, Poi Ngian and Mohamad Zin, Rosli and Abd. Latif, Siti Asma (2023) Compression resistance of short cold-formed lipped C channel section with web stiffening. In: 6th International Conference on Architecture and Civil Engineering, ICACE 2022, 18 August 2022, Kuala Lumpur, Malaysia. http://dx.doi.org/10.1007/978-981-19-8024-4_35
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Goh, Yong Sheng
Tan, Hean Seong
Shek, Poi Ngian
Mohamad Zin, Rosli
Abd. Latif, Siti Asma
Compression resistance of short cold-formed lipped C channel section with web stiffening
description This paper presents the compression resistance of the short cold-formed lipped C channel section after being strengthened with a web stiffener. The failure modes of short cold-formed lipped C channel section with web stiffening under axial compression load are also investigated in this research. Furthermore, the comparison has been made between the short column with and without stiffener in terms of ultimate load capacity and failure mode. The web stiffener which is a steel plate of 100 mm in width and 6.2 mm in thickness is connected to the web of the specimen using bolted and welded connection. For bolted connections, three different spacing between bolt is proposed to determine the effect of the spacing toward the compressive strength of the specimen. Two failure modes, local buckling and distortional buckling, are observed during the experiment. From the comparison, the compression resistance of column with web stiffener has increased significantly. The increment in strength is in the range from 0.25 to 1.00. For the column with web stiffening, compression resistance for the different connection methods is compared. The welding connection reached the highest ultimate load capacity. The theoretical prediction using BS EN 1993: 1-3 [8] shows good agreement with the experimental result.
format Conference or Workshop Item
author Goh, Yong Sheng
Tan, Hean Seong
Shek, Poi Ngian
Mohamad Zin, Rosli
Abd. Latif, Siti Asma
author_facet Goh, Yong Sheng
Tan, Hean Seong
Shek, Poi Ngian
Mohamad Zin, Rosli
Abd. Latif, Siti Asma
author_sort Goh, Yong Sheng
title Compression resistance of short cold-formed lipped C channel section with web stiffening
title_short Compression resistance of short cold-formed lipped C channel section with web stiffening
title_full Compression resistance of short cold-formed lipped C channel section with web stiffening
title_fullStr Compression resistance of short cold-formed lipped C channel section with web stiffening
title_full_unstemmed Compression resistance of short cold-formed lipped C channel section with web stiffening
title_sort compression resistance of short cold-formed lipped c channel section with web stiffening
publishDate 2023
url http://eprints.utm.my/107894/
http://dx.doi.org/10.1007/978-981-19-8024-4_35
_version_ 1814043551889096704