Typical tests on cold-formed steel structures

Cold-formed steel has been recently brought into Malaysian construction. It is a steelwork technology that has high potential to be developed in Malaysia, that can offers advantages such as fast erection, lightweight, clean and easier construction. This paper reported a series of research studies ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Tahir, Mahmood, Tan, Cher Siang, Shek, Poi Ngian
Format: Conference or Workshop Item
Language:English
Published: 2006
Subjects:
Online Access:http://eprints.utm.my/id/eprint/682/1/MahmoodMdTahir2006_Typicaltestsoncoldformedsteel.pdf
http://eprints.utm.my/id/eprint/682/
http://civil.utm.my/apsec2015/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.682
record_format eprints
spelling my.utm.6822017-08-23T00:21:07Z http://eprints.utm.my/id/eprint/682/ Typical tests on cold-formed steel structures Md. Tahir, Mahmood Tan, Cher Siang Shek, Poi Ngian TA Engineering (General). Civil engineering (General) Cold-formed steel has been recently brought into Malaysian construction. It is a steelwork technology that has high potential to be developed in Malaysia, that can offers advantages such as fast erection, lightweight, clean and easier construction. This paper reported a series of research studies carried out in UTM for locally produced coldformed steel sections and roof truss system. The research work included study on the member capacities for lipped C-section and Hat-section, a full-scale test for roof truss system and the cold-formed steel tek-screw connection capacities. All the studies were based on the requirements of British Standard BS 5950 Part 5 1998. The actual capacities of the proposed sections were ratio from 1.09 - 2.21 compared to the design strength. The full-scale experimental test on roof truss also achieved two times of the estimated design capacities. The tek-screw connection capacities in resistance to shear force and pull-out force ranged 76% - 141% higher than the design requirements. The connection also withstand 10000 times of dynamic load that verified its performance in long-term serviceability. The results of the experimental tests on the proposed cold-formed steel section and roof truss system showed good agreement to the requirements of BS5950 Part 5 1998. 2006-09 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/682/1/MahmoodMdTahir2006_Typicaltestsoncoldformedsteel.pdf Md. Tahir, Mahmood and Tan, Cher Siang and Shek, Poi Ngian (2006) Typical tests on cold-formed steel structures. In: 6th Asia-Pacific Structural Engineering and Construction Conference, 5-6 September 2006, Kuala Lumpur, Malaysia. http://civil.utm.my/apsec2015/
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Md. Tahir, Mahmood
Tan, Cher Siang
Shek, Poi Ngian
Typical tests on cold-formed steel structures
description Cold-formed steel has been recently brought into Malaysian construction. It is a steelwork technology that has high potential to be developed in Malaysia, that can offers advantages such as fast erection, lightweight, clean and easier construction. This paper reported a series of research studies carried out in UTM for locally produced coldformed steel sections and roof truss system. The research work included study on the member capacities for lipped C-section and Hat-section, a full-scale test for roof truss system and the cold-formed steel tek-screw connection capacities. All the studies were based on the requirements of British Standard BS 5950 Part 5 1998. The actual capacities of the proposed sections were ratio from 1.09 - 2.21 compared to the design strength. The full-scale experimental test on roof truss also achieved two times of the estimated design capacities. The tek-screw connection capacities in resistance to shear force and pull-out force ranged 76% - 141% higher than the design requirements. The connection also withstand 10000 times of dynamic load that verified its performance in long-term serviceability. The results of the experimental tests on the proposed cold-formed steel section and roof truss system showed good agreement to the requirements of BS5950 Part 5 1998.
format Conference or Workshop Item
author Md. Tahir, Mahmood
Tan, Cher Siang
Shek, Poi Ngian
author_facet Md. Tahir, Mahmood
Tan, Cher Siang
Shek, Poi Ngian
author_sort Md. Tahir, Mahmood
title Typical tests on cold-formed steel structures
title_short Typical tests on cold-formed steel structures
title_full Typical tests on cold-formed steel structures
title_fullStr Typical tests on cold-formed steel structures
title_full_unstemmed Typical tests on cold-formed steel structures
title_sort typical tests on cold-formed steel structures
publishDate 2006
url http://eprints.utm.my/id/eprint/682/1/MahmoodMdTahir2006_Typicaltestsoncoldformedsteel.pdf
http://eprints.utm.my/id/eprint/682/
http://civil.utm.my/apsec2015/
_version_ 1643643159680385024