Thermoacoustic resonance effect and circuit modelling of biological tissue
In this letter, thermoacoustic resonance effect is predicted from theoretical analysis with series resistor-inductor-capacitor resonance circuit model and then observed experimentally using muscle tissue illuminated by multi-pulse microwave source. Through model fitting, the circuit parameters are e...
Saved in:
Main Authors: | , , , |
---|---|
其他作者: | |
格式: | Article |
語言: | English |
出版: |
2013
|
在線閱讀: | https://hdl.handle.net/10356/100405 http://hdl.handle.net/10220/10992 |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
機構: | Nanyang Technological University |
語言: | English |
總結: | In this letter, thermoacoustic resonance effect is predicted from theoretical analysis with series resistor-inductor-capacitor resonance circuit model and then observed experimentally using muscle tissue illuminated by multi-pulse microwave source. Through model fitting, the circuit parameters are extracted to characterize quantitatively the resonant response of the tissue. Coherent demodulation is applied to obtain the enhanced signal-to-noise ratio and spatial information by treating tissue as a communication channel. This physical phenomenon shows significantly higher sensitivity than conventional single microwave pulse induced thermoacoustic effect, enabling the potential design of low-power thermoacoustic imaging device for portable and on-site diagnosis. |
---|