Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples
Multispectral Mueller matrix imaging was performed over a spectral range from 470 to 632 nm on 4-μm unstained gastric tissue sections. A complete set of polarization parameters was derived. The combination of linear depolarization and linear retardance yields the highest accuracy in sample classific...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/104203 http://hdl.handle.net/10220/19543 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-104203 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1042032023-12-29T06:49:49Z Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples Wang, Wenfeng Lim, Lee Guan Srivastava, Supriya Yan, Jimmy So Bok Shabbir, Asim Liu, Quan School of Chemical and Biomedical Engineering DRNTU::Engineering::Chemical engineering::Biotechnology Multispectral Mueller matrix imaging was performed over a spectral range from 470 to 632 nm on 4-μm unstained gastric tissue sections. A complete set of polarization parameters was derived. The combination of linear depolarization and linear retardance yields the highest accuracy in sample classification. When the depolarization of linearly polarized light due to scattering is independent of the orientation angle of the incident linear polarization vector, the derivation of linear polarization properties will require only 3×3 Mueller matrix, which would significantly reduce the complexity of the polarimetry imaging system. When additional parameters are needed to complement the two linear polarization parameters, retardance, circular depolarization, and depolarization can be included in classification in the order of preference. However, these additional parameters would require the measurement of 4×4 Mueller matrix. In addition, it appears that wavelength is not a critical factor in terms of classification accuracy for thin tissue sections in this study. Published version 2014-06-04T02:39:46Z 2019-12-06T21:28:25Z 2014-06-04T02:39:46Z 2019-12-06T21:28:25Z 2014 2014 Journal Article Wang, W., Lim, L. G., Srivastava, S., Yan, J. S. B., Shabbir, A., & Liu, Q. (2014). Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples . Journal of Biomedical Optics, 19(4), 046020-. 1083-3668 https://hdl.handle.net/10356/104203 http://hdl.handle.net/10220/19543 10.1117/1.JBO.19.4.046020 en Journal of biomedical optics © 2014 Society of Photo-Optical Instrumentation Engineers (SPIE). This paper was published in Journal of Biomedical Optics and is made available as an electronic reprint (preprint) with permission of Society of Photo-Optical Instrumentation Engineers (SPIE). The paper can be found at the following official DOI: http://dx.doi.org/10.1117/1.JBO.19.4.046020. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Chemical engineering::Biotechnology |
spellingShingle |
DRNTU::Engineering::Chemical engineering::Biotechnology Wang, Wenfeng Lim, Lee Guan Srivastava, Supriya Yan, Jimmy So Bok Shabbir, Asim Liu, Quan Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
description |
Multispectral Mueller matrix imaging was performed over a spectral range from 470 to 632 nm on 4-μm unstained gastric tissue sections. A complete set of polarization parameters was derived. The combination of linear depolarization and linear retardance yields the highest accuracy in sample classification. When the depolarization of linearly polarized light due to scattering is independent of the orientation angle of the incident linear polarization vector, the derivation of linear polarization properties will require only 3×3 Mueller matrix, which would significantly reduce the complexity of the polarimetry imaging system. When additional parameters are needed to complement the two linear polarization parameters, retardance, circular depolarization, and depolarization can be included in classification in the order of preference. However, these additional parameters would require the measurement of 4×4 Mueller matrix. In addition, it appears that wavelength is not a critical factor in terms of classification accuracy for thin tissue sections in this study. |
author2 |
School of Chemical and Biomedical Engineering |
author_facet |
School of Chemical and Biomedical Engineering Wang, Wenfeng Lim, Lee Guan Srivastava, Supriya Yan, Jimmy So Bok Shabbir, Asim Liu, Quan |
format |
Article |
author |
Wang, Wenfeng Lim, Lee Guan Srivastava, Supriya Yan, Jimmy So Bok Shabbir, Asim Liu, Quan |
author_sort |
Wang, Wenfeng |
title |
Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
title_short |
Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
title_full |
Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
title_fullStr |
Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
title_full_unstemmed |
Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
title_sort |
roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples |
publishDate |
2014 |
url |
https://hdl.handle.net/10356/104203 http://hdl.handle.net/10220/19543 |
_version_ |
1787136640212271104 |