A modified one-cycle-control-based active power filter for harmonic compensation

This paper proposes a modified one cycle control (OCC) for active power filter (APF) to compensate only harmonic components of load currents. The conventional OCC-based APF cannot differentiate between the harmonic and reactive components of load currents, which leads to the increment in device curr...

Full description

Saved in:
Bibliographic Details
Main Authors: Wang, Lei, Han, Xiaoqing, Ren, Chunguang, Yang, Yu, Wang, Peng
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/140490
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-140490
record_format dspace
spelling sg-ntu-dr.10356-1404902020-05-29T08:27:05Z A modified one-cycle-control-based active power filter for harmonic compensation Wang, Lei Han, Xiaoqing Ren, Chunguang Yang, Yu Wang, Peng School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Active Power Filter (APF) Harmonic Compensation This paper proposes a modified one cycle control (OCC) for active power filter (APF) to compensate only harmonic components of load currents. The conventional OCC-based APF cannot differentiate between the harmonic and reactive components of load currents, which leads to the increment in device current rating because of compensation of large reactive currents besides harmonics. The reference signals of the OCC control core have been reconstructed and the associated control equations have been developed, following the control philosophy of simplicity. The modified scheme is easy to implement and only three more sensors are required for measuring load currents compared with the conventional OCC. This modified OCC guarantees the excellent performance of harmonic compensation alone and retains the advantages of the conventional OCC, such as no phase locking loop and the constant switching frequency. The feasibility and performance of the proposed OCC has been validated by experimental studies on a 5 kVA APF hardware platform developed in laboratory. 2020-05-29T08:27:05Z 2020-05-29T08:27:05Z 2017 Journal Article Wang, L., Han, X., Ren, C., Yang, Y., & Wang, P. (2018). A modified one-cycle-control-based active power filter for harmonic compensation. IEEE Transactions on Industrial Electronics, 65(1), 738-748. doi:10.1109/TIE.2017.2682021 0278-0046 https://hdl.handle.net/10356/140490 10.1109/TIE.2017.2682021 2-s2.0-85040703916 1 65 738 748 en IEEE Transactions on Industrial Electronics © 2017 IEEE. All rights reserved.
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
Active Power Filter (APF)
Harmonic Compensation
spellingShingle Engineering::Electrical and electronic engineering
Active Power Filter (APF)
Harmonic Compensation
Wang, Lei
Han, Xiaoqing
Ren, Chunguang
Yang, Yu
Wang, Peng
A modified one-cycle-control-based active power filter for harmonic compensation
description This paper proposes a modified one cycle control (OCC) for active power filter (APF) to compensate only harmonic components of load currents. The conventional OCC-based APF cannot differentiate between the harmonic and reactive components of load currents, which leads to the increment in device current rating because of compensation of large reactive currents besides harmonics. The reference signals of the OCC control core have been reconstructed and the associated control equations have been developed, following the control philosophy of simplicity. The modified scheme is easy to implement and only three more sensors are required for measuring load currents compared with the conventional OCC. This modified OCC guarantees the excellent performance of harmonic compensation alone and retains the advantages of the conventional OCC, such as no phase locking loop and the constant switching frequency. The feasibility and performance of the proposed OCC has been validated by experimental studies on a 5 kVA APF hardware platform developed in laboratory.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Wang, Lei
Han, Xiaoqing
Ren, Chunguang
Yang, Yu
Wang, Peng
format Article
author Wang, Lei
Han, Xiaoqing
Ren, Chunguang
Yang, Yu
Wang, Peng
author_sort Wang, Lei
title A modified one-cycle-control-based active power filter for harmonic compensation
title_short A modified one-cycle-control-based active power filter for harmonic compensation
title_full A modified one-cycle-control-based active power filter for harmonic compensation
title_fullStr A modified one-cycle-control-based active power filter for harmonic compensation
title_full_unstemmed A modified one-cycle-control-based active power filter for harmonic compensation
title_sort modified one-cycle-control-based active power filter for harmonic compensation
publishDate 2020
url https://hdl.handle.net/10356/140490
_version_ 1681058579657785344