Affimer sandwich probes for stable and robust lateral flow assaying

Lateral flow assays (LFAs) widely deployed for on-site diagnosis have predominantly utilized antibodies as recognition molecules. Antibodies with limited thermal stability deteriorate the performance of the LFA over time. Herein, we demonstrate a stable and robust LFA by utilizing thermally stable p...

Full description

Saved in:
Bibliographic Details
Main Authors: Goyal, Garima, Sharma, Antareep, Tok, Alfred Iing Yoong, Palaniappan, Alagappan, Liedberg, Bo
Other Authors: School of Materials Science and Engineering
Format: Article
Language:English
Published: 2022
Subjects:
Online Access:https://hdl.handle.net/10356/161863
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-161863
record_format dspace
spelling sg-ntu-dr.10356-1618632022-09-22T05:22:57Z Affimer sandwich probes for stable and robust lateral flow assaying Goyal, Garima Sharma, Antareep Tok, Alfred Iing Yoong Palaniappan, Alagappan Liedberg, Bo School of Materials Science and Engineering Interdisciplinary Graduate School (IGS) Centre for Biomimetic Sensor Science (CBSS) Engineering::Materials Affimer Magnetic Beads Lateral flow assays (LFAs) widely deployed for on-site diagnosis have predominantly utilized antibodies as recognition molecules. Antibodies with limited thermal stability deteriorate the performance of the LFA over time. Herein, we demonstrate a stable and robust LFA by utilizing thermally stable peptide-based 12-14 kDa affimers as recognition molecules, in lieu of conventional protein-based antibodies to analyze complex samples with a significantly improved shelf life at room temperature. The model system studied here is that of interleukin-8 (IL8) biomarker for validating the efficacy of the proposed approach, using a pair of affimer probes that demonstrates dual functionality of capturing and reporting. Affimers immobilized on the test zone of LFA serve as capture probes for IL8-affimer-MB complexes. Whereas affimers conjugated with the MBs that enable extraction of IL8 from the sample matrix serve as reporters for visual detection. The MB complexes captured at the test zone resulted in brownish test bands that enable concentration-dependent detection of IL8. The assay yielded sensitive visual detection of IL8 at ng/mL levels (~ 0.1 ng/mL and 1 ng/mL in buffer and human plasma, respectively), within 20 min, using sample volumes of ~ 100 µL. Importantly, the stability of affimer-incorporated LFA improved significantly in contrast to antibody-incorporated LFA over time, even when stored at 4 °C. Therefore, the proposed affimer-based LFA in conjunction with MBs offer stable and reliable detection of biomarkers at clinically relevant concentration ranges in complicated matrices, even without requiring cold storage, hence, offering a promising avenue for on-site diagnosis in resource-limited settings. Nanyang Technological University The Institute for Nanomedicine jointly established between Northwestern University and Nanyang Technological University provided fnancial support 2022-09-22T05:22:57Z 2022-09-22T05:22:57Z 2022 Journal Article Goyal, G., Sharma, A., Tok, A. I. Y., Palaniappan, A. & Liedberg, B. (2022). Affimer sandwich probes for stable and robust lateral flow assaying. Analytical and Bioanalytical Chemistry, 414(14), 4245-4254. https://dx.doi.org/10.1007/s00216-022-04078-4 1618-2642 https://hdl.handle.net/10356/161863 10.1007/s00216-022-04078-4 35426494 2-s2.0-85128231123 14 414 4245 4254 en Analytical and Bioanalytical Chemistry © 2022 Springer-Verlag GmbH Germany, part of Springer Nature. All rights reserved.
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Materials
Affimer
Magnetic Beads
spellingShingle Engineering::Materials
Affimer
Magnetic Beads
Goyal, Garima
Sharma, Antareep
Tok, Alfred Iing Yoong
Palaniappan, Alagappan
Liedberg, Bo
Affimer sandwich probes for stable and robust lateral flow assaying
description Lateral flow assays (LFAs) widely deployed for on-site diagnosis have predominantly utilized antibodies as recognition molecules. Antibodies with limited thermal stability deteriorate the performance of the LFA over time. Herein, we demonstrate a stable and robust LFA by utilizing thermally stable peptide-based 12-14 kDa affimers as recognition molecules, in lieu of conventional protein-based antibodies to analyze complex samples with a significantly improved shelf life at room temperature. The model system studied here is that of interleukin-8 (IL8) biomarker for validating the efficacy of the proposed approach, using a pair of affimer probes that demonstrates dual functionality of capturing and reporting. Affimers immobilized on the test zone of LFA serve as capture probes for IL8-affimer-MB complexes. Whereas affimers conjugated with the MBs that enable extraction of IL8 from the sample matrix serve as reporters for visual detection. The MB complexes captured at the test zone resulted in brownish test bands that enable concentration-dependent detection of IL8. The assay yielded sensitive visual detection of IL8 at ng/mL levels (~ 0.1 ng/mL and 1 ng/mL in buffer and human plasma, respectively), within 20 min, using sample volumes of ~ 100 µL. Importantly, the stability of affimer-incorporated LFA improved significantly in contrast to antibody-incorporated LFA over time, even when stored at 4 °C. Therefore, the proposed affimer-based LFA in conjunction with MBs offer stable and reliable detection of biomarkers at clinically relevant concentration ranges in complicated matrices, even without requiring cold storage, hence, offering a promising avenue for on-site diagnosis in resource-limited settings.
author2 School of Materials Science and Engineering
author_facet School of Materials Science and Engineering
Goyal, Garima
Sharma, Antareep
Tok, Alfred Iing Yoong
Palaniappan, Alagappan
Liedberg, Bo
format Article
author Goyal, Garima
Sharma, Antareep
Tok, Alfred Iing Yoong
Palaniappan, Alagappan
Liedberg, Bo
author_sort Goyal, Garima
title Affimer sandwich probes for stable and robust lateral flow assaying
title_short Affimer sandwich probes for stable and robust lateral flow assaying
title_full Affimer sandwich probes for stable and robust lateral flow assaying
title_fullStr Affimer sandwich probes for stable and robust lateral flow assaying
title_full_unstemmed Affimer sandwich probes for stable and robust lateral flow assaying
title_sort affimer sandwich probes for stable and robust lateral flow assaying
publishDate 2022
url https://hdl.handle.net/10356/161863
_version_ 1745574636385468416