Ultrasonic devices for trapping and transportation of medicine pills
In this final year project, ultrasonic techniques are explored in the view to collect, separate and transport small particles. Current existing ultrasonic actuators are only able to trap micro-scale particles in the air. The heaviest particle that can be collected by the current technology is the...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/17112 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | In this final year project, ultrasonic techniques are explored in the view to collect, separate
and transport small particles.
Current existing ultrasonic actuators are only able to trap micro-scale particles in the air. The
heaviest particle that can be collected by the current technology is the grass seed
(0.00038g/particle) [18]. Thus in this project, a Dual L-Shaped metal strips ultrasonic
actuator is built that has the ability to collect small-scale particles in the air. This actuator is
competent to collect a particle that is at least 65 times heavier than what the current actuators
can do. The trapping capability of this actuator is investigated.
In order to maintain the weight of the various shapes of pill, clay had been used to make the
pill. With this, the experiments produced a more accurate result as it eliminated the
discrepancy in weight. More specific experiments had been conducted to identify the
different factors affecting the trapping capability. These include shape of the pill and
orientation of the pill. Through the experiments, it was realized that the trapping capability of
the pill is proportional to the surface area of the pill, in contact with the tip of the actuator.
Besides that, there is also an experiment to investigate the height of water level rise due to the
varying length of the actuator, submerged in 2 different mediums – water and oil. In this
experiment, the aluminum plate is dipped into the medium and the height of water level rise
is recorded. This is done repeated, varying the length of the actuator, submerged in the
medium. From this experiment, the optimized length of the actuator, submerged in the
medium, that induced the highest water level rise is 3cm. Furthermore, it is also noticed that
there is a memorizing effect as the water level rise did not drop back to the original level
upon switching off of the power supply.
Through these experiments, many factors, affecting the trapping capability of the actuator,
were identified. Besides that, some problems, regarding the setup and procedures of the
experiment, were also recognized. As such, various recommendations, pertaining to the
problems, were listed in the Chapter 15 of the report. |
---|