Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing
Objective: In the theories of pulse disgnosis in traditional Chinese medicine (TCM), it is emphasized that pulse manifestations at the radial artery within the wrist (called Cunkou) signify the physiological and pathological conditions of different internal organs in the human body. However, differe...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2024
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/181763 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-181763 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1817632024-12-17T01:15:46Z Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing Shi, Yubing Yang, Hongyi Yeo, Joon Hock School of Mechanical and Aerospace Engineering Engineering Pulse manifestation Tactile sensing Objective: In the theories of pulse disgnosis in traditional Chinese medicine (TCM), it is emphasized that pulse manifestations at the radial artery within the wrist (called Cunkou) signify the physiological and pathological conditions of different internal organs in the human body. However, different opinions exist among researchers about the objectiveness of the pulse diagnosis technique. Some researchers mentioned that no significant differences were observed in pulse manifestations at various Cunkou areas, hence there might be some difficulty in evaluating the status of different organs through checking pulse manifestations at Cunkou. This research aims to analyze the pulse response at Cunkou from the aspect of the characteristics of tactile sensing, thus to give a preliminary explanation to the above question. Methods: This research utilized the Weber-Fechner law to model the tactile sensing as a dynamic low-pass signal filter with varying bandwidths under different compression levels during pulse diagnosis. The model was applied to analyzing the clinical data collected previously by our group. The arterial pressures measured invasively with equipment from 14 patients with aorta coarctation were processed to simulate different pulse manifestations at Cun, Guan, and Chi positions of Cunkou when different compression levels were applied. Results: Due to the characteristics of tactile sensing, significant variations were observed in pulse manifestations at different pulse-depths under the application of changing compression levels; while no such changes in pulse manifestations were observed from the employment of transducer only, without tactile sensing involved. The results explained why different understandings on pulse manifestations were formed between direct pulse-taking technique in TCM and modern sphygmography using transducers. The features of pulse manifestations at Cunkou, using direct pulse-taking technique but at different depths, superficial, middle, and deep positions, respectively, predicted by the developed tactile sensing model were in line with those described in TCM pulse theories. Conclusion: Based on the developed tactile sensing model, this study preliminarily explains the phenomenon that pulse manifestation at Cunkou changes in response to the compression force applied during TCM pulse-taking. Integrating the tactile sensing model with the study of TCM pulse diagnosis opens a new chapter for visualizing and quantitatively interpreting pulse manifestations. This not only expands the scope of pulse diagnosis study effectively, but also provide a scientific basis for further technical upgrading and optimization of existing pulse diagnosis equipment. Published version Fundings: Ministry of Science, Technology and Innovation, Malaysia (06-02-12-SF0247), Natural Science Foundation of Shaanxi Province, China (2021JM-468), and Administration of Traditional Chinese Medicine of Shaanxi Province, China (SZY-KJCYC-2023-018). 2024-12-17T01:15:46Z 2024-12-17T01:15:46Z 2024 Journal Article Shi, Y., Yang, H. & Yeo, J. H. (2024). Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing. Digital Chinese Medicine, 7(1), 29-39. https://dx.doi.org/10.1016/j.dcmed.2024.04.004 2096-479X https://hdl.handle.net/10356/181763 10.1016/j.dcmed.2024.04.004 2-s2.0-85197095094 1 7 29 39 en Digital Chinese Medicine © 2024 The Authors. Production and hosting by Elsevier B.V. This is an open access article under the Creative Commons Attribution License, which permits unrestricted use and redistribution provided that the original author and source are credited. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering Pulse manifestation Tactile sensing |
spellingShingle |
Engineering Pulse manifestation Tactile sensing Shi, Yubing Yang, Hongyi Yeo, Joon Hock Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
description |
Objective: In the theories of pulse disgnosis in traditional Chinese medicine (TCM), it is emphasized that pulse manifestations at the radial artery within the wrist (called Cunkou) signify the physiological and pathological conditions of different internal organs in the human body. However, different opinions exist among researchers about the objectiveness of the pulse diagnosis technique. Some researchers mentioned that no significant differences were observed in pulse manifestations at various Cunkou areas, hence there might be some difficulty in evaluating the status of different organs through checking pulse manifestations at Cunkou. This research aims to analyze the pulse response at Cunkou from the aspect of the characteristics of tactile sensing, thus to give a preliminary explanation to the above question. Methods: This research utilized the Weber-Fechner law to model the tactile sensing as a dynamic low-pass signal filter with varying bandwidths under different compression levels during pulse diagnosis. The model was applied to analyzing the clinical data collected previously by our group. The arterial pressures measured invasively with equipment from 14 patients with aorta coarctation were processed to simulate different pulse manifestations at Cun, Guan, and Chi positions of Cunkou when different compression levels were applied. Results: Due to the characteristics of tactile sensing, significant variations were observed in pulse manifestations at different pulse-depths under the application of changing compression levels; while no such changes in pulse manifestations were observed from the employment of transducer only, without tactile sensing involved. The results explained why different understandings on pulse manifestations were formed between direct pulse-taking technique in TCM and modern sphygmography using transducers. The features of pulse manifestations at Cunkou, using direct pulse-taking technique but at different depths, superficial, middle, and deep positions, respectively, predicted by the developed tactile sensing model were in line with those described in TCM pulse theories. Conclusion: Based on the developed tactile sensing model, this study preliminarily explains the phenomenon that pulse manifestation at Cunkou changes in response to the compression force applied during TCM pulse-taking. Integrating the tactile sensing model with the study of TCM pulse diagnosis opens a new chapter for visualizing and quantitatively interpreting pulse manifestations. This not only expands the scope of pulse diagnosis study effectively, but also provide a scientific basis for further technical upgrading and optimization of existing pulse diagnosis equipment. |
author2 |
School of Mechanical and Aerospace Engineering |
author_facet |
School of Mechanical and Aerospace Engineering Shi, Yubing Yang, Hongyi Yeo, Joon Hock |
format |
Article |
author |
Shi, Yubing Yang, Hongyi Yeo, Joon Hock |
author_sort |
Shi, Yubing |
title |
Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
title_short |
Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
title_full |
Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
title_fullStr |
Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
title_full_unstemmed |
Differences in pulse manifestations at Cunkou based on simplified modeling of tactile sensing |
title_sort |
differences in pulse manifestations at cunkou based on simplified modeling of tactile sensing |
publishDate |
2024 |
url |
https://hdl.handle.net/10356/181763 |
_version_ |
1819113077783658496 |