Direct liquid cooling of simulated electronic chips in a rectangular channel
Experiments are performed to study the single-phase forced convection heat transfer and subcooled flow boiling heat transfer from an in-line four simulated chips in a rectangular channel using water and FC-72. The experimental data of single-phase heat transfer cover the laminar flow and turbulent f...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/19998 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-19998 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-199982023-03-11T17:07:28Z Direct liquid cooling of simulated electronic chips in a rectangular channel Xu, Guo Ping. Tso, Chin Ping School of Mechanical and Production Engineering DRNTU::Engineering::Mechanical engineering Experiments are performed to study the single-phase forced convection heat transfer and subcooled flow boiling heat transfer from an in-line four simulated chips in a rectangular channel using water and FC-72. The experimental data of single-phase heat transfer cover the laminar flow and turbulent flow with Reynolds number based on chip length (Z,=10 mm)ranging from 6xl02 to 8xl04 for an inlet temperature of T^25°C. The effects of geometrical parameters such as chip number, channel height (H=0.5, 0.7, 1.0)and protruding height (B=0, 0.1, 0.2), and working fluid (water, Pr=6.0, FC-72, Pr=11.5)are studied. Transitional Reynolds number and flow regimes are deduced from the heat transfer data. The experimental results from single-phase heat transfer indicate that the heat transfer coefficient is strongly affected by Reynolds number and protruding height, and weakly by channel height. Fully-developed values of heat transfer coefficient are reached after the third chip. Results from the present study of water cooling agree well with results from the literature for air-cooling of electronic components at the similar conditions, when Prandtl number scaling is considered. The experimental results from FC-72 are similar to those from water for flush-mounted chips, but are on the high end when protruding chips are used. Doctor of Philosophy (MPE) 2009-12-14T07:56:40Z 2009-12-14T07:56:40Z 1998 1998 Thesis http://hdl.handle.net/10356/19998 en NANYANG TECHNOLOGICAL UNIVERSITY 228 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Mechanical engineering |
spellingShingle |
DRNTU::Engineering::Mechanical engineering Xu, Guo Ping. Direct liquid cooling of simulated electronic chips in a rectangular channel |
description |
Experiments are performed to study the single-phase forced convection heat transfer and subcooled flow boiling heat transfer from an in-line four simulated chips in a rectangular channel using water and FC-72. The experimental data of single-phase heat transfer cover the laminar flow and turbulent flow with Reynolds number based on chip length (Z,=10 mm)ranging from 6xl02 to 8xl04 for an inlet temperature of T^25°C. The effects of geometrical parameters such as chip number, channel height (H=0.5, 0.7, 1.0)and protruding height (B=0, 0.1, 0.2), and working fluid (water, Pr=6.0, FC-72, Pr=11.5)are studied. Transitional Reynolds number and flow regimes are deduced from the heat transfer data. The experimental results from single-phase heat transfer indicate that the heat transfer coefficient is strongly affected by Reynolds number and protruding height, and weakly by channel height. Fully-developed values of heat transfer coefficient are reached after the third chip. Results from the present study of water cooling agree well with results from the literature for air-cooling of electronic components at the similar conditions, when Prandtl number scaling is considered. The experimental results from FC-72 are similar to those from water for flush-mounted chips, but are on the high end when protruding chips are used. |
author2 |
Tso, Chin Ping |
author_facet |
Tso, Chin Ping Xu, Guo Ping. |
format |
Theses and Dissertations |
author |
Xu, Guo Ping. |
author_sort |
Xu, Guo Ping. |
title |
Direct liquid cooling of simulated electronic chips in a rectangular channel |
title_short |
Direct liquid cooling of simulated electronic chips in a rectangular channel |
title_full |
Direct liquid cooling of simulated electronic chips in a rectangular channel |
title_fullStr |
Direct liquid cooling of simulated electronic chips in a rectangular channel |
title_full_unstemmed |
Direct liquid cooling of simulated electronic chips in a rectangular channel |
title_sort |
direct liquid cooling of simulated electronic chips in a rectangular channel |
publishDate |
2009 |
url |
http://hdl.handle.net/10356/19998 |
_version_ |
1761781529935085568 |