Design of finger holder for non-invasive blood glucose level measurement

Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundame...

Full description

Saved in:
Bibliographic Details
Main Author: Loh, Eileen Yi Ling.
Other Authors: Yeo Joon Hock
Format: Final Year Project
Language:English
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10356/45064
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-45064
record_format dspace
spelling sg-ntu-dr.10356-450642023-03-04T19:34:34Z Design of finger holder for non-invasive blood glucose level measurement Loh, Eileen Yi Ling. Yeo Joon Hock School of Mechanical and Aerospace Engineering GlucoStats System DRNTU::Engineering::Mechanical engineering::Bio-mechatronics Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundamental living body signal for disease diagnosis. The style of existent pulse wave can reflects the health of individual. However, when accuracy of measurement is concern, the pulse wave will hinder the accuracy of the measurement. This project aims to reduce the motion cause by the pulse in the vein of the measure finger by mechanical means. In this report, the author presents the design and development of finger holder for blood glucose measurement. Study of anthropometric of the human will gives a better understanding on the design requirement for the design. This report will also be reviewing the previous work done, current mechanical design and functions. The pros and cons of the design and improvisation will be analyzed. Being a modular design is the main advantage of the design, where future work could take place with minimal changes made. Bachelor of Engineering (Mechanical Engineering) 2011-06-08T08:31:04Z 2011-06-08T08:31:04Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/45064 en Nanyang Technological University 60 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
spellingShingle DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
Loh, Eileen Yi Ling.
Design of finger holder for non-invasive blood glucose level measurement
description Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundamental living body signal for disease diagnosis. The style of existent pulse wave can reflects the health of individual. However, when accuracy of measurement is concern, the pulse wave will hinder the accuracy of the measurement. This project aims to reduce the motion cause by the pulse in the vein of the measure finger by mechanical means. In this report, the author presents the design and development of finger holder for blood glucose measurement. Study of anthropometric of the human will gives a better understanding on the design requirement for the design. This report will also be reviewing the previous work done, current mechanical design and functions. The pros and cons of the design and improvisation will be analyzed. Being a modular design is the main advantage of the design, where future work could take place with minimal changes made.
author2 Yeo Joon Hock
author_facet Yeo Joon Hock
Loh, Eileen Yi Ling.
format Final Year Project
author Loh, Eileen Yi Ling.
author_sort Loh, Eileen Yi Ling.
title Design of finger holder for non-invasive blood glucose level measurement
title_short Design of finger holder for non-invasive blood glucose level measurement
title_full Design of finger holder for non-invasive blood glucose level measurement
title_fullStr Design of finger holder for non-invasive blood glucose level measurement
title_full_unstemmed Design of finger holder for non-invasive blood glucose level measurement
title_sort design of finger holder for non-invasive blood glucose level measurement
publishDate 2011
url http://hdl.handle.net/10356/45064
_version_ 1759854261318975488