Design of finger holder for non-invasive blood glucose level measurement
Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundame...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/45064 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-45064 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-450642023-03-04T19:34:34Z Design of finger holder for non-invasive blood glucose level measurement Loh, Eileen Yi Ling. Yeo Joon Hock School of Mechanical and Aerospace Engineering GlucoStats System DRNTU::Engineering::Mechanical engineering::Bio-mechatronics Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundamental living body signal for disease diagnosis. The style of existent pulse wave can reflects the health of individual. However, when accuracy of measurement is concern, the pulse wave will hinder the accuracy of the measurement. This project aims to reduce the motion cause by the pulse in the vein of the measure finger by mechanical means. In this report, the author presents the design and development of finger holder for blood glucose measurement. Study of anthropometric of the human will gives a better understanding on the design requirement for the design. This report will also be reviewing the previous work done, current mechanical design and functions. The pros and cons of the design and improvisation will be analyzed. Being a modular design is the main advantage of the design, where future work could take place with minimal changes made. Bachelor of Engineering (Mechanical Engineering) 2011-06-08T08:31:04Z 2011-06-08T08:31:04Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/45064 en Nanyang Technological University 60 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Mechanical engineering::Bio-mechatronics |
spellingShingle |
DRNTU::Engineering::Mechanical engineering::Bio-mechatronics Loh, Eileen Yi Ling. Design of finger holder for non-invasive blood glucose level measurement |
description |
Diabetes is one of the leading illnesses in the world. Aside from what diabetes can cause other illness to arise. The patient also experienced discomfort during medical test. A non-invasive medical measurement device needed to cater to this ever-growing group of user. Pulse wave is basic yet fundamental living body signal for disease diagnosis. The style of existent pulse wave can reflects the health of individual. However, when accuracy of measurement is concern, the pulse wave will hinder the accuracy of the measurement.
This project aims to reduce the motion cause by the pulse in the vein of the measure finger by mechanical means. In this report, the author presents the design and development of finger holder for blood glucose measurement. Study of anthropometric of the human will gives a better understanding on the design requirement for the design. This report will also be reviewing the previous work done, current mechanical design and functions. The pros and cons of the design and improvisation will be analyzed.
Being a modular design is the main advantage of the design, where future work could take place with minimal changes made. |
author2 |
Yeo Joon Hock |
author_facet |
Yeo Joon Hock Loh, Eileen Yi Ling. |
format |
Final Year Project |
author |
Loh, Eileen Yi Ling. |
author_sort |
Loh, Eileen Yi Ling. |
title |
Design of finger holder for non-invasive blood glucose level measurement |
title_short |
Design of finger holder for non-invasive blood glucose level measurement |
title_full |
Design of finger holder for non-invasive blood glucose level measurement |
title_fullStr |
Design of finger holder for non-invasive blood glucose level measurement |
title_full_unstemmed |
Design of finger holder for non-invasive blood glucose level measurement |
title_sort |
design of finger holder for non-invasive blood glucose level measurement |
publishDate |
2011 |
url |
http://hdl.handle.net/10356/45064 |
_version_ |
1759854261318975488 |