Development of composite hollow fiber membranes with strong mechanical strength for PRO application

Pressure retarded osmosis (PRO) is one of the promising processes in catering large amount of renewable energy from salt and fresh waters, through utilization of osmotic driving force. A desirable PRO membrane should possess high water permeability as well as low salt permeability. Salt rejection le...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Jun Xiang
Other Authors: Wang Rong
Format: Final Year Project
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/64444
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-64444
record_format dspace
spelling sg-ntu-dr.10356-644442023-03-03T17:23:01Z Development of composite hollow fiber membranes with strong mechanical strength for PRO application Lim, Jun Xiang Wang Rong School of Civil and Environmental Engineering Singapore Membrane Technology Centre DRNTU::Engineering::Environmental engineering::Water supply Pressure retarded osmosis (PRO) is one of the promising processes in catering large amount of renewable energy from salt and fresh waters, through utilization of osmotic driving force. A desirable PRO membrane should possess high water permeability as well as low salt permeability. Salt rejection level should be as high as possible, while maintaining low structural parameter to minimize the effect of internal polarization (ICP). The membrane should have high mechanical strength to resist the high pressure applied in the draw solution. In this study, the objective is to develop thin-film composite (TFC) hollow fiber membranes with high mechanical strength for PRO applications. TFC hollow fiber membranes were fabricated, characterized and evaluated for their PRO performances. Polyether sulfone (PES) and Polyetherimide (PEI) polymers were used to fabricate the substrates through non-solvent induced phase inversion (NIPS) method. Interfacial polymerization was used to fabricate polyamide active layer for all the membranes in this study. TFC-PEI membranes generally possessed higher mechanical strength than TFC-PES membranes, allowing higher pressure to be applied to produce more power output. Other than PRO test, TFC membranes in this report were tested for the repeatability of their performance as well as PRO performance under sustained high pressure for more than 20 hours to test their commercial viability. The best newly fabricated TFC hollow fiber membrane in this report achieved a power density of 14.8 W/m2 at operating pressure of 12.6 bar, and it is by a TFC-PEI hollow fiber membrane. This pressure applied was also tested to prove that the performance of the TFC-PEI membrane can sustain for the long-term operation run. Such test was not conducted before for previous PRO membranes studies according to author’s knowledge. Synthetic seawater brine (1.0 M NaCl) was used as draw solution and freshwater (DI water) as the feed solution. The TFC hollow fiber membrane also achieved good water flux of 41.3 L/m2.h and low specific salt flux value of 0.01 M. Despite the ability to sustain long term PRO operation, there are still room for improvement for the PRO performance of the TFC membranes to achieve higher power density and mechanical strength. Better long-term stability PRO performance test procedures should be implemented in future work as well to test for PRO membranes’ long term commercial application. Bachelor of Engineering (Environmental Engineering) 2015-05-26T09:11:02Z 2015-05-26T09:11:02Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/64444 en Nanyang Technological University 66 p. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Environmental engineering::Water supply
spellingShingle DRNTU::Engineering::Environmental engineering::Water supply
Lim, Jun Xiang
Development of composite hollow fiber membranes with strong mechanical strength for PRO application
description Pressure retarded osmosis (PRO) is one of the promising processes in catering large amount of renewable energy from salt and fresh waters, through utilization of osmotic driving force. A desirable PRO membrane should possess high water permeability as well as low salt permeability. Salt rejection level should be as high as possible, while maintaining low structural parameter to minimize the effect of internal polarization (ICP). The membrane should have high mechanical strength to resist the high pressure applied in the draw solution. In this study, the objective is to develop thin-film composite (TFC) hollow fiber membranes with high mechanical strength for PRO applications. TFC hollow fiber membranes were fabricated, characterized and evaluated for their PRO performances. Polyether sulfone (PES) and Polyetherimide (PEI) polymers were used to fabricate the substrates through non-solvent induced phase inversion (NIPS) method. Interfacial polymerization was used to fabricate polyamide active layer for all the membranes in this study. TFC-PEI membranes generally possessed higher mechanical strength than TFC-PES membranes, allowing higher pressure to be applied to produce more power output. Other than PRO test, TFC membranes in this report were tested for the repeatability of their performance as well as PRO performance under sustained high pressure for more than 20 hours to test their commercial viability. The best newly fabricated TFC hollow fiber membrane in this report achieved a power density of 14.8 W/m2 at operating pressure of 12.6 bar, and it is by a TFC-PEI hollow fiber membrane. This pressure applied was also tested to prove that the performance of the TFC-PEI membrane can sustain for the long-term operation run. Such test was not conducted before for previous PRO membranes studies according to author’s knowledge. Synthetic seawater brine (1.0 M NaCl) was used as draw solution and freshwater (DI water) as the feed solution. The TFC hollow fiber membrane also achieved good water flux of 41.3 L/m2.h and low specific salt flux value of 0.01 M. Despite the ability to sustain long term PRO operation, there are still room for improvement for the PRO performance of the TFC membranes to achieve higher power density and mechanical strength. Better long-term stability PRO performance test procedures should be implemented in future work as well to test for PRO membranes’ long term commercial application.
author2 Wang Rong
author_facet Wang Rong
Lim, Jun Xiang
format Final Year Project
author Lim, Jun Xiang
author_sort Lim, Jun Xiang
title Development of composite hollow fiber membranes with strong mechanical strength for PRO application
title_short Development of composite hollow fiber membranes with strong mechanical strength for PRO application
title_full Development of composite hollow fiber membranes with strong mechanical strength for PRO application
title_fullStr Development of composite hollow fiber membranes with strong mechanical strength for PRO application
title_full_unstemmed Development of composite hollow fiber membranes with strong mechanical strength for PRO application
title_sort development of composite hollow fiber membranes with strong mechanical strength for pro application
publishDate 2015
url http://hdl.handle.net/10356/64444
_version_ 1759854157407191040