Development of a fluidic flowmeter for water flow rate measurements
Accurate flow rate measurement is of prime importance in many areas such as combustion control, gas or water flowmetering and plant monitoring. The target fluidic flowmeter is a new type of flowmeter which is still being researched into. It has a large turn-down ratio, good linearity and can detect...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Research Report |
Published: |
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/7008 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
id |
sg-ntu-dr.10356-7008 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-70082023-03-04T18:09:58Z Development of a fluidic flowmeter for water flow rate measurements Lua, Aik Chong. School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Fluid mechanics Accurate flow rate measurement is of prime importance in many areas such as combustion control, gas or water flowmetering and plant monitoring. The target fluidic flowmeter is a new type of flowmeter which is still being researched into. It has a large turn-down ratio, good linearity and can detect very low flow rates. A target flowmeter for water measurements was designed and fabricated. The geometry of the flowmeter could be varied so that the study of each geometrical parameter on the flowmeter performance could be carried out independently. A constant temperature anemometer DANTEC 56C was used in conjunction with the fibre-film probe. The signal from the fibre-film sensor was sent to an HP35670A Dynamical Signal Analyzer to determine the oscillation frequency. The flow rate was obtained accurately by weighing the water collected in a tank. 2008-09-18T05:58:52Z 2008-09-18T05:58:52Z 2005 2005 Research Report http://hdl.handle.net/10356/7008 Nanyang Technological University application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
topic |
DRNTU::Engineering::Mechanical engineering::Fluid mechanics |
spellingShingle |
DRNTU::Engineering::Mechanical engineering::Fluid mechanics Lua, Aik Chong. Development of a fluidic flowmeter for water flow rate measurements |
description |
Accurate flow rate measurement is of prime importance in many areas such as combustion control, gas or water flowmetering and plant monitoring. The target fluidic flowmeter is a new type of flowmeter which is still being researched into. It has a large turn-down ratio, good linearity and can detect very low flow rates. A target flowmeter for water measurements was designed and fabricated. The geometry of the flowmeter could be varied so that the study of each geometrical parameter on the flowmeter performance could be carried out independently. A constant temperature anemometer DANTEC 56C was used in conjunction with the fibre-film probe. The signal from the fibre-film sensor was sent to an HP35670A Dynamical Signal Analyzer to determine the oscillation frequency. The flow rate was obtained accurately by weighing the water collected in a tank. |
author2 |
School of Mechanical and Aerospace Engineering |
author_facet |
School of Mechanical and Aerospace Engineering Lua, Aik Chong. |
format |
Research Report |
author |
Lua, Aik Chong. |
author_sort |
Lua, Aik Chong. |
title |
Development of a fluidic flowmeter for water flow rate measurements |
title_short |
Development of a fluidic flowmeter for water flow rate measurements |
title_full |
Development of a fluidic flowmeter for water flow rate measurements |
title_fullStr |
Development of a fluidic flowmeter for water flow rate measurements |
title_full_unstemmed |
Development of a fluidic flowmeter for water flow rate measurements |
title_sort |
development of a fluidic flowmeter for water flow rate measurements |
publishDate |
2008 |
url |
http://hdl.handle.net/10356/7008 |
_version_ |
1759858236434939904 |