Sensitivity analysis of the beam optics of a superconducting gantry for proton therapy

A superconducting gantry design is proposed to reduce the size, weight, and complexity of the gantry in the proton therapy facility in Paul Scherrer Institut (PSI), Switzerland. In this thesis, two beam optics programmes, namely TRANSPORT and COSY INFINITY 9.1, have been used to determine the mo...

全面介紹

Saved in:
書目詳細資料
主要作者: Wongso, Shelvia
其他作者: Chew Lock Yue
格式: Final Year Project
語言:English
出版: 2018
主題:
在線閱讀:http://hdl.handle.net/10356/74951
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Nanyang Technological University
語言: English
實物特徵
總結:A superconducting gantry design is proposed to reduce the size, weight, and complexity of the gantry in the proton therapy facility in Paul Scherrer Institut (PSI), Switzerland. In this thesis, two beam optics programmes, namely TRANSPORT and COSY INFINITY 9.1, have been used to determine the most sensitive magnets in the new gantry beam line with respect to mechanical shift and varying eld strength. The sensitivity analysis is crucial considering the required precision of the pencil beam to hit the tumour at the targeted position within 0.5 mm error with beam size deviation of not more than 0.5 mm. The analysis with both programmes has veri ed that the second normal conducting quadrupole in the beam line is a very sensitive element with respect to horizontal misalignment ( 0.17 mm) while both of the normal conducting quadrupoles are very sensitive with respect to vertical misalignment (0.15 mm). Furthermore, the two normal conducting quadrupoles possess small tolerance of approximately 2.3 T/m with respect to variation in eld strength. It was also found that the phase spaces changed the most when the eld strengths of the superconducting magnets were altered. The tolerance range in each magnet presented in this thesis serves as a gauge for the precision required when designing and mounting the magnets. The values are also important when necessary improvement and corrections to the beam line are considered in order to deliver the desirable beam size at the correct location.