Partial compressive behaviour of concrete-filled stainless steel tubes stub columns
This report aims to investigate the structural performance of self-compacting concrete-filled stainless steel tube under partial compression. 8 partial compressive concrete-filled stainless steel tubes specimens and 1 entire compressive reference concrete-filled stainless steel tubes specimens were...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2019
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/78578 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | This report aims to investigate the structural performance of self-compacting concrete-filled stainless steel tube under partial compression. 8 partial compressive concrete-filled stainless steel tubes specimens and 1 entire compressive reference concrete-filled stainless steel tubes specimens were used in throughout the experiment to assess the effect of cross-section of stainless circular hollow section, infilled concrete strength, partial compressive area shape and ratio on the failure mode, loaddisplacement response and bearing capacity of the concrete-filled stainless steel tubes columns. The experimental results indicated that the partial compressive area ratio was the main reason affecting the failure modes and bearing strengths of concrete-filled stainless steel tubes columns, which would clearly deteriorate the resistance of concrete-filled stainless steel tubes column as the partial compressive area ratio increased. When the confinement factor of the concrete-filled stainless steel tubes column reduces, the relative capacity index of the partial compressive concrete-filled stainless steel tubes column slightly decreases. The partial compressive shape was found to have negligible effect on the resistances of concrete-filled stainless steel tubes columns under the same partial compressive area ratios. Given that there have been no established design standards for partial compressive concrete-filled stainless steel tubes member, the corresponding design rules for concrete filled carbon steel tube members, as set out in the European code and American Specification and Australia/New Zealand standard, were evaluated for partial compressive concrete-filled stainless steel tubes stub columns, revealing unsafe and inaccurate partial compression resistance predictions. |
---|