Partial compressive behaviour of concrete-filled stainless steel tubes stub columns
This report aims to investigate the structural performance of self-compacting concrete-filled stainless steel tube under partial compression. 8 partial compressive concrete-filled stainless steel tubes specimens and 1 entire compressive reference concrete-filled stainless steel tubes specimens were...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Final Year Project |
Language: | English |
Published: |
2019
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/78578 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-78578 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-785782023-03-03T17:04:52Z Partial compressive behaviour of concrete-filled stainless steel tubes stub columns Low, Yee Yew Zhao Ou School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering This report aims to investigate the structural performance of self-compacting concrete-filled stainless steel tube under partial compression. 8 partial compressive concrete-filled stainless steel tubes specimens and 1 entire compressive reference concrete-filled stainless steel tubes specimens were used in throughout the experiment to assess the effect of cross-section of stainless circular hollow section, infilled concrete strength, partial compressive area shape and ratio on the failure mode, loaddisplacement response and bearing capacity of the concrete-filled stainless steel tubes columns. The experimental results indicated that the partial compressive area ratio was the main reason affecting the failure modes and bearing strengths of concrete-filled stainless steel tubes columns, which would clearly deteriorate the resistance of concrete-filled stainless steel tubes column as the partial compressive area ratio increased. When the confinement factor of the concrete-filled stainless steel tubes column reduces, the relative capacity index of the partial compressive concrete-filled stainless steel tubes column slightly decreases. The partial compressive shape was found to have negligible effect on the resistances of concrete-filled stainless steel tubes columns under the same partial compressive area ratios. Given that there have been no established design standards for partial compressive concrete-filled stainless steel tubes member, the corresponding design rules for concrete filled carbon steel tube members, as set out in the European code and American Specification and Australia/New Zealand standard, were evaluated for partial compressive concrete-filled stainless steel tubes stub columns, revealing unsafe and inaccurate partial compression resistance predictions. Bachelor of Engineering (Civil) 2019-06-24T03:01:12Z 2019-06-24T03:01:12Z 2019 Final Year Project (FYP) http://hdl.handle.net/10356/78578 en Nanyang Technological University 41 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Civil engineering |
spellingShingle |
DRNTU::Engineering::Civil engineering Low, Yee Yew Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
description |
This report aims to investigate the structural performance of self-compacting concrete-filled stainless steel tube under partial compression. 8 partial compressive concrete-filled stainless steel tubes specimens and 1 entire compressive reference concrete-filled stainless steel tubes specimens were used in throughout the experiment to assess the effect of cross-section of stainless circular hollow section, infilled concrete strength, partial compressive area shape and ratio on the failure mode, loaddisplacement response and bearing capacity of the concrete-filled stainless steel tubes columns. The experimental results indicated that the partial compressive area ratio was the main reason affecting the failure modes and bearing strengths of concrete-filled stainless steel tubes columns, which would clearly deteriorate the resistance of concrete-filled stainless steel tubes column as the partial compressive area ratio increased. When the confinement factor of the concrete-filled stainless steel tubes column reduces, the relative capacity index of the partial compressive concrete-filled stainless steel tubes column slightly decreases. The partial compressive shape was found to have negligible effect on the resistances of concrete-filled stainless steel tubes columns under the same partial compressive area ratios. Given that there have been no established design standards for partial compressive concrete-filled stainless steel tubes member, the corresponding design rules for concrete filled carbon steel tube members, as set out in the European code and American Specification and Australia/New Zealand standard, were evaluated for partial compressive concrete-filled stainless steel tubes stub columns, revealing unsafe and inaccurate partial compression resistance predictions. |
author2 |
Zhao Ou |
author_facet |
Zhao Ou Low, Yee Yew |
format |
Final Year Project |
author |
Low, Yee Yew |
author_sort |
Low, Yee Yew |
title |
Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
title_short |
Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
title_full |
Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
title_fullStr |
Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
title_full_unstemmed |
Partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
title_sort |
partial compressive behaviour of concrete-filled stainless steel tubes stub columns |
publishDate |
2019 |
url |
http://hdl.handle.net/10356/78578 |
_version_ |
1759856926431117312 |