Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages

Ablation was carried out on high voltage Schottky rectifiers at 25°C and -5°C (with a thermoelectric cooler or TEC), at 1.0 W and 3.9 W of laser power. In-situ measurement of the reverse current was conducted and correlated to the device junction temperature. It was found that the usage of a TEC inc...

Full description

Saved in:
Bibliographic Details
Main Authors: Kor, H. B., Chang, A. C. K., Gan, C. L.
Other Authors: School of Materials Science & Engineering
Format: Conference or Workshop Item
Language:English
Published: 2012
Subjects:
Online Access:https://hdl.handle.net/10356/94719
http://hdl.handle.net/10220/8186
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-94719
record_format dspace
spelling sg-ntu-dr.10356-947192023-07-08T05:41:04Z Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages Kor, H. B. Chang, A. C. K. Gan, C. L. School of Materials Science & Engineering International Symposium on the Physical and Failure Analysis of Integrated Circuits (17th : 2010 : Singapore) DRNTU::Engineering::Materials Ablation was carried out on high voltage Schottky rectifiers at 25°C and -5°C (with a thermoelectric cooler or TEC), at 1.0 W and 3.9 W of laser power. In-situ measurement of the reverse current was conducted and correlated to the device junction temperature. It was found that the usage of a TEC increases the number of laser scans to reach the set current compliance of 100 μA after exposing the die, for ablation at 3.9 W, although eventual damage to the device is still unavoidable. The incorporation of a TEC below the sample is also demonstrated to be effective in reducing the device junction temperature during laser ablation. 2012-06-01T01:26:04Z 2019-12-06T19:01:01Z 2012-06-01T01:26:04Z 2019-12-06T19:01:01Z 2010 2010 Conference Paper Kor, H. B., Chang, A. C. K. & Gan, C. L. (2010). Temperature Control with a Thermoelectric Cooler (TEC) during Laser Decapsulation of Plastic Packages. In The 17th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA), pp. 1-6. https://hdl.handle.net/10356/94719 http://hdl.handle.net/10220/8186 10.1109/IPFA.2010.5531987 160450 en © 2010 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [DOI: http://dx.doi.org/10.1109/IPFA.2010.5531987 ] application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic DRNTU::Engineering::Materials
spellingShingle DRNTU::Engineering::Materials
Kor, H. B.
Chang, A. C. K.
Gan, C. L.
Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
description Ablation was carried out on high voltage Schottky rectifiers at 25°C and -5°C (with a thermoelectric cooler or TEC), at 1.0 W and 3.9 W of laser power. In-situ measurement of the reverse current was conducted and correlated to the device junction temperature. It was found that the usage of a TEC increases the number of laser scans to reach the set current compliance of 100 μA after exposing the die, for ablation at 3.9 W, although eventual damage to the device is still unavoidable. The incorporation of a TEC below the sample is also demonstrated to be effective in reducing the device junction temperature during laser ablation.
author2 School of Materials Science & Engineering
author_facet School of Materials Science & Engineering
Kor, H. B.
Chang, A. C. K.
Gan, C. L.
format Conference or Workshop Item
author Kor, H. B.
Chang, A. C. K.
Gan, C. L.
author_sort Kor, H. B.
title Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
title_short Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
title_full Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
title_fullStr Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
title_full_unstemmed Temperature control with a thermoelectric cooler (TEC) during laser decapsulation of plastic packages
title_sort temperature control with a thermoelectric cooler (tec) during laser decapsulation of plastic packages
publishDate 2012
url https://hdl.handle.net/10356/94719
http://hdl.handle.net/10220/8186
_version_ 1772827726493777920