Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content
Tissue plasminogen activator (tPA) remains the only drug for recanalization in acute ischemic stroke, and the dose is determined by the patient's body-weight. Properties of the blood clot as well as ultrasound exposure might affect the thrombolysis outcome. In this study, clot was prepared by m...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2013
|
Online Access: | https://hdl.handle.net/10356/96098 http://hdl.handle.net/10220/10088 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-96098 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-960982023-03-04T17:07:47Z Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content Zhou, Yufeng Sharma, Vijay Kumar Murugappan, Kanna Suresh Ahmad, Aftab School of Mechanical and Aerospace Engineering International Symposium on Therapeutic Ultrasound (12th : 2012 : Heidelberg, Germany) Tissue plasminogen activator (tPA) remains the only drug for recanalization in acute ischemic stroke, and the dose is determined by the patient's body-weight. Properties of the blood clot as well as ultrasound exposure might affect the thrombolysis outcome. In this study, clot was prepared by mixing horse blood with CaCl2 solution and cholesterin up to 1.0 mg/ml. To simulate the aging effect serum was replaced by fresh blood periodically. 225 IU/ml of tPA was used to initiate lysis. Clot was exposed to continuous 2 MHz transcranial Doppler ultrasound at acoustic intensity of 340 mW/cm2. The weight of the blood clot increased with its age (from 37.28±2.87 mg at 2 hrs to 51.56±5.34 mg at 10 hrs, p < 0.05). Although no difference between clot-cholesterol levels and thrombolysis with ultrasound or tPA alone was found, combination of these modalities induced significant lysis in the clots with cholesterol levels of more than 0.5 mg/ml (clot-weight reduced by 41.68±2.3%) as compared to clots with normal cholesterol (30.60±4.10%; p < 0.05). Altogether, sonothrombolysis seems to work better in fresh thrombi with high-cholesterol levels. Published version 2013-06-10T02:44:06Z 2019-12-06T19:25:39Z 2013-06-10T02:44:06Z 2019-12-06T19:25:39Z 2012 2012 Conference Paper Zhou, Y., Sharma, V. K., Murugappan, K. S., & Ahmad, A. (2012). Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content, pp. 227-232. https://hdl.handle.net/10356/96098 http://hdl.handle.net/10220/10088 10.1063/1.4769949 en © 2012 American Institute of Physics. This paper was published in 12th International Symposium on Therapeutic Ultrasound and is made available as an electronic reprint (preprint) with permission of American Institute of Physics. The paper can be found at the following official DOI: [http://dx.doi.org/10.1063/1.4769949]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
description |
Tissue plasminogen activator (tPA) remains the only drug for recanalization in acute ischemic stroke, and the dose is determined by the patient's body-weight. Properties of the blood clot as well as ultrasound exposure might affect the thrombolysis outcome. In this study, clot was prepared by mixing horse blood with CaCl2 solution and cholesterin up to 1.0 mg/ml. To simulate the aging effect serum was replaced by fresh blood periodically. 225 IU/ml of tPA was used to initiate lysis. Clot was exposed to continuous 2 MHz transcranial Doppler ultrasound at acoustic intensity of 340 mW/cm2. The weight of the blood clot increased with its age (from 37.28±2.87 mg at 2 hrs to 51.56±5.34 mg at 10 hrs, p < 0.05). Although no difference between clot-cholesterol levels and thrombolysis with ultrasound or tPA alone was found, combination of these modalities induced significant lysis in the clots with cholesterol levels of more than 0.5 mg/ml (clot-weight reduced by 41.68±2.3%) as compared to clots with normal cholesterol (30.60±4.10%; p < 0.05). Altogether, sonothrombolysis seems to work better in fresh thrombi with high-cholesterol levels. |
author2 |
School of Mechanical and Aerospace Engineering |
author_facet |
School of Mechanical and Aerospace Engineering Zhou, Yufeng Sharma, Vijay Kumar Murugappan, Kanna Suresh Ahmad, Aftab |
format |
Conference or Workshop Item |
author |
Zhou, Yufeng Sharma, Vijay Kumar Murugappan, Kanna Suresh Ahmad, Aftab |
spellingShingle |
Zhou, Yufeng Sharma, Vijay Kumar Murugappan, Kanna Suresh Ahmad, Aftab Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
author_sort |
Zhou, Yufeng |
title |
Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
title_short |
Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
title_full |
Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
title_fullStr |
Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
title_full_unstemmed |
Clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
title_sort |
clot dissolution is better with ultrasound assisted thrombolysis for fresh clots with higher cholesterol content |
publishDate |
2013 |
url |
https://hdl.handle.net/10356/96098 http://hdl.handle.net/10220/10088 |
_version_ |
1759856380727001088 |