The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis

In this study, the effects of threshold variation in image segmentation of micro CT images of cancellous bone in the determination of the architectural parameters and stiffness were investigated. A total of 42 samples of 6 × 6 × 6 mm3 cubes with threshold values set between 500–1100 greyscale in inc...

Full description

Saved in:
Bibliographic Details
Main Authors: Yan, Ya-Bo, Qi, Wei, Qiu, Tian-Xia, Teo, Ee-Chon, Lei, Wei
Other Authors: School of Mechanical and Aerospace Engineering
Format: Article
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/96286
http://hdl.handle.net/10220/11438
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-96286
record_format dspace
spelling sg-ntu-dr.10356-962862020-03-07T13:22:15Z The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis Yan, Ya-Bo Qi, Wei Qiu, Tian-Xia Teo, Ee-Chon Lei, Wei School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Bio-mechatronics In this study, the effects of threshold variation in image segmentation of micro CT images of cancellous bone in the determination of the architectural parameters and stiffness were investigated. A total of 42 samples of 6 × 6 × 6 mm3 cubes with threshold values set between 500–1100 greyscale in increment of 100 of CT images of six human C5 vertebral bodies were analyzed. Threshold value of 800, based on Otsu's method, was set for the control group. From various threshold values, the respective architectural parameters, and the corresponding stiffness in three orthotropic directions (Exx, Eyy, Ezz) of each cube were computed from the voxel-based micro-finite element models under compressive simulation. The results showed that 1% variation of threshold value resulted in a 3.4% variation in BV/TV, 2% in Tb.N, 3.1% in Tb.Th, 2.9% in BS/BV, 1.8% in Tb.Sp, 29.2% in Exx, 28.7% Eyy and 27.7% in Ezz. Statistical analysis showed that 2.9% threshold variation caused significant change in BV/TV, Tb.Th, Exx, Eyy and Ezz values. The study shows that with threshold variation of more than 2.9%, significant differences in the architectural parameters and stiffness compared to those based on Otsu's method. 2013-07-15T07:12:43Z 2019-12-06T19:28:11Z 2013-07-15T07:12:43Z 2019-12-06T19:28:11Z 2012 2012 Journal Article Yan, Y.-B., Qi, W., Qiu, T.-X., Teo, E.-C., & Lei, W. (2012). The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis. Journal of Mechanics in Medicine and Biology, 12(05), 1250092-. https://hdl.handle.net/10356/96286 http://hdl.handle.net/10220/11438 10.1142/S0219519412500923 en Journal of mechanics in medicine and biology © 2012 World Scientific Publishing Co.
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
spellingShingle DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
Yan, Ya-Bo
Qi, Wei
Qiu, Tian-Xia
Teo, Ee-Chon
Lei, Wei
The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
description In this study, the effects of threshold variation in image segmentation of micro CT images of cancellous bone in the determination of the architectural parameters and stiffness were investigated. A total of 42 samples of 6 × 6 × 6 mm3 cubes with threshold values set between 500–1100 greyscale in increment of 100 of CT images of six human C5 vertebral bodies were analyzed. Threshold value of 800, based on Otsu's method, was set for the control group. From various threshold values, the respective architectural parameters, and the corresponding stiffness in three orthotropic directions (Exx, Eyy, Ezz) of each cube were computed from the voxel-based micro-finite element models under compressive simulation. The results showed that 1% variation of threshold value resulted in a 3.4% variation in BV/TV, 2% in Tb.N, 3.1% in Tb.Th, 2.9% in BS/BV, 1.8% in Tb.Sp, 29.2% in Exx, 28.7% Eyy and 27.7% in Ezz. Statistical analysis showed that 2.9% threshold variation caused significant change in BV/TV, Tb.Th, Exx, Eyy and Ezz values. The study shows that with threshold variation of more than 2.9%, significant differences in the architectural parameters and stiffness compared to those based on Otsu's method.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Yan, Ya-Bo
Qi, Wei
Qiu, Tian-Xia
Teo, Ee-Chon
Lei, Wei
format Article
author Yan, Ya-Bo
Qi, Wei
Qiu, Tian-Xia
Teo, Ee-Chon
Lei, Wei
author_sort Yan, Ya-Bo
title The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
title_short The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
title_full The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
title_fullStr The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
title_full_unstemmed The effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
title_sort effect of threshold value on the architectural parameters and stiffness of human cancellous bone in micro ct analysis
publishDate 2013
url https://hdl.handle.net/10356/96286
http://hdl.handle.net/10220/11438
_version_ 1681036980606992384