Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay
We developed two sets of a multiplex amplification refractory mutation system (M-ARMS) assay to identify specific β-thalassemia (β-thal) mutations that are common in Thailand. The first one was for the detection of mutants with codon 17 (A>T), IV S-I-1 (G >T)), codons 41/42 (-TCT T) and codons...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-47949088545&partnerID=40&md5=4852ebc27b79005da2832a37eadf24cf http://cmuir.cmu.ac.th/handle/6653943832/2402 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-2402 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-24022014-08-30T02:00:48Z Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay Mirasena S. Shimbhu D. Sanguansermsri M. Sanguansermsri T. We developed two sets of a multiplex amplification refractory mutation system (M-ARMS) assay to identify specific β-thalassemia (β-thal) mutations that are common in Thailand. The first one was for the detection of mutants with codon 17 (A>T), IV S-I-1 (G >T)), codons 41/42 (-TCT T) and codons 71/72 (+A), while the second one was for the -87 (C>A), -28 (A>G) and IVS-II-654 (C>T). Application of the proposed assay to 282 persons with β-thal trait revealed a positive result in 276 cases (97.8%). There were 258 cases (91.5%) positive for the set 1 M-ARMS assay and 18 cases (6.4%) were positive for set 2. Six cases (2.2%) were negative for both sets 1 and 2, and were further characterized by DNA sequencing. The mutations detected by the set 1 M-ARMS assay were 113 cases (40.1%) of codons 41/42, 95 (33.7%) of codon 17, 41 (14.5%) of IVS-I-1 and nine cases (3.2%) of codons 71/72, while by set 2 there were 12 cases (4.2%) of -28, four cases(1.4%) of -87 and two cases (0.7%) of IVS-II-654. Mutations undetectable by M-ARMS assay were two cases of codons 27/28 (+C), one case of codon 35 (C>A), one of codon 43 (G>T), one of -31 (A>G) and one of IVS-I-5 (C>G). The M-ARMS assay proved to be a valuable tool for the analysis of β-thal mutations. The method is robust, accurate, simple, speedy and cost-effective. The application of this assay will facilitate genetic counseling and prenatal diagnosis for severe thalassemia in high-risk pregnancies. Copyright © Informa Healthcare USA, Inc. 2014-08-30T02:00:48Z 2014-08-30T02:00:48Z 2008 Article 03630269 10.1080/03630260701798391 18654891 HEMOD http://www.scopus.com/inward/record.url?eid=2-s2.0-47949088545&partnerID=40&md5=4852ebc27b79005da2832a37eadf24cf http://cmuir.cmu.ac.th/handle/6653943832/2402 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
We developed two sets of a multiplex amplification refractory mutation system (M-ARMS) assay to identify specific β-thalassemia (β-thal) mutations that are common in Thailand. The first one was for the detection of mutants with codon 17 (A>T), IV S-I-1 (G >T)), codons 41/42 (-TCT T) and codons 71/72 (+A), while the second one was for the -87 (C>A), -28 (A>G) and IVS-II-654 (C>T). Application of the proposed assay to 282 persons with β-thal trait revealed a positive result in 276 cases (97.8%). There were 258 cases (91.5%) positive for the set 1 M-ARMS assay and 18 cases (6.4%) were positive for set 2. Six cases (2.2%) were negative for both sets 1 and 2, and were further characterized by DNA sequencing. The mutations detected by the set 1 M-ARMS assay were 113 cases (40.1%) of codons 41/42, 95 (33.7%) of codon 17, 41 (14.5%) of IVS-I-1 and nine cases (3.2%) of codons 71/72, while by set 2 there were 12 cases (4.2%) of -28, four cases(1.4%) of -87 and two cases (0.7%) of IVS-II-654. Mutations undetectable by M-ARMS assay were two cases of codons 27/28 (+C), one case of codon 35 (C>A), one of codon 43 (G>T), one of -31 (A>G) and one of IVS-I-5 (C>G). The M-ARMS assay proved to be a valuable tool for the analysis of β-thal mutations. The method is robust, accurate, simple, speedy and cost-effective. The application of this assay will facilitate genetic counseling and prenatal diagnosis for severe thalassemia in high-risk pregnancies. Copyright © Informa Healthcare USA, Inc. |
format |
Article |
author |
Mirasena S. Shimbhu D. Sanguansermsri M. Sanguansermsri T. |
spellingShingle |
Mirasena S. Shimbhu D. Sanguansermsri M. Sanguansermsri T. Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
author_facet |
Mirasena S. Shimbhu D. Sanguansermsri M. Sanguansermsri T. |
author_sort |
Mirasena S. |
title |
Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
title_short |
Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
title_full |
Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
title_fullStr |
Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
title_full_unstemmed |
Detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
title_sort |
detection of β-thalassemia mutations using a multiplex amplification refractory mutation system assay |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-47949088545&partnerID=40&md5=4852ebc27b79005da2832a37eadf24cf http://cmuir.cmu.ac.th/handle/6653943832/2402 |
_version_ |
1681419851964350464 |