Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors

© 2017 IEEE. This work presents cost evaluation of current uprating of overhead transmission lines by using Aluminum Conductor Steel Reinforced (ACSR) and High Temperature Low Sag (HTLS) conductors. The evaluation method is carried out based on twofold and fourfold ampacities, under both normal and...

Full description

Saved in:
Bibliographic Details
Main Authors: Nuchprayoon S., Chaichana A.
Format: Conference Proceeding
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026746617&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40278
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40278
record_format dspace
spelling th-cmuir.6653943832-402782017-09-28T04:08:41Z Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors Nuchprayoon S. Chaichana A. © 2017 IEEE. This work presents cost evaluation of current uprating of overhead transmission lines by using Aluminum Conductor Steel Reinforced (ACSR) and High Temperature Low Sag (HTLS) conductors. The evaluation method is carried out based on twofold and fourfold ampacities, under both normal and stressed operating conditions. The test case is a 230-kV, double-circuit, transmission lines using 1272 MCM ACSR conductors. The candidate conductors are five types of HTLS conductors with comparable size. The cost components under consideration are demolition cost, construction and installation costs, conductor cost, cost of energy losses, and land cost. Upon evaluation of the total costs, the selection criteria of proper conductor are proposed. 2017-09-28T04:08:41Z 2017-09-28T04:08:41Z Conference Proceeding 2-s2.0-85026746617 10.1109/EEEIC.2017.7977606 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026746617&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40278
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2017 IEEE. This work presents cost evaluation of current uprating of overhead transmission lines by using Aluminum Conductor Steel Reinforced (ACSR) and High Temperature Low Sag (HTLS) conductors. The evaluation method is carried out based on twofold and fourfold ampacities, under both normal and stressed operating conditions. The test case is a 230-kV, double-circuit, transmission lines using 1272 MCM ACSR conductors. The candidate conductors are five types of HTLS conductors with comparable size. The cost components under consideration are demolition cost, construction and installation costs, conductor cost, cost of energy losses, and land cost. Upon evaluation of the total costs, the selection criteria of proper conductor are proposed.
format Conference Proceeding
author Nuchprayoon S.
Chaichana A.
spellingShingle Nuchprayoon S.
Chaichana A.
Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
author_facet Nuchprayoon S.
Chaichana A.
author_sort Nuchprayoon S.
title Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
title_short Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
title_full Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
title_fullStr Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
title_full_unstemmed Cost evaluation of current uprating of overhead transmission lines using ACSR and HTLS conductors
title_sort cost evaluation of current uprating of overhead transmission lines using acsr and htls conductors
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026746617&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40278
_version_ 1681421780334411776