High-performance liquid chromatographic method for the analysis of fluconazole in pharmaceutical preparations

High-performance liquid chromatographic method was developed for the analysis of fluconazole in pharmaceutical preparations. The analyzed drug was separated on a reversed-phase column [Hypersil ODS column (120 x 46 mm, 5 μm particle size)] , using a mobile phase containing methanol: 10 mM pH 7.0 pho...

Full description

Saved in:
Bibliographic Details
Main Authors: Limpiti D., Lhieochaiphant D., O-ariyakul N.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84991061167&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42314
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Description
Summary:High-performance liquid chromatographic method was developed for the analysis of fluconazole in pharmaceutical preparations. The analyzed drug was separated on a reversed-phase column [Hypersil ODS column (120 x 46 mm, 5 μm particle size)] , using a mobile phase containing methanol: 10 mM pH 7.0 phosphate buffer (50:50) with UV detection at 260 nm. The proposed method is specific, sensitive, reproducible and reliable. It can be successfully applied as a stability-indicating method for the determination of fluconazole in pharmaceutical preparations. With a run time of less than 2 minutes, the method is rapid and easy to use for routine analysis of fluconazole in pure form and dosage form as well as for its dissolution testing.