Development of method for determination of lead, iodine, and protein content in fish sauce

The aim of this investigation was to develop a method for the determination of the lead, iodine, and protein content in fish sauce. For statistical data, five samples of fish sauce that cost 9.0-43.0 Bahts were randomly bought from a supermarket in Chiang Mai Province. Five replicates of each sample...

Full description

Saved in:
Bibliographic Details
Main Authors: Somjing Roongjang, Umaporn Pusod, Prapart Phooviang, Khesorn Nantachit
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84963969157&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/53942
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-53942
record_format dspace
spelling th-cmuir.6653943832-539422018-09-04T10:03:10Z Development of method for determination of lead, iodine, and protein content in fish sauce Somjing Roongjang Umaporn Pusod Prapart Phooviang Khesorn Nantachit Multidisciplinary The aim of this investigation was to develop a method for the determination of the lead, iodine, and protein content in fish sauce. For statistical data, five samples of fish sauce that cost 9.0-43.0 Bahts were randomly bought from a supermarket in Chiang Mai Province. Five replicates of each sample were digested and measured for the lead amount, using absorbance by atomic absorption spectroscopy, and each replication was injected six times. The iodine content were measured from the five samples, and each sample was investigated in five replications using the iodimetric method. The protein contents was determined by applying the Kjedahl method using the five samples. The lead determination method was accepted because of the statistical data. Using fish sauce as a seasoning agent is a practice that is safe from lead toxicity because the lead contents were found to be lower than the stipulated Thai Food Act Limit which is 1.0 ppm. The determination method for iodine content needs to be further developed by controlling the pH of the reaction medium to be neutral or to be that of a dilute acid. The protein determination method needs to be investigated for more statistical data. Consumers should also pay better attention to the sample label because it was observed in this investigation that there was a highly priced sample contained low nutritional values of protein besides showing the wrong label. 2018-09-04T10:03:10Z 2018-09-04T10:03:10Z 2014-01-01 Journal 16851994 2-s2.0-84963969157 10.12982/cmujns.2014.0043 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84963969157&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/53942
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Multidisciplinary
spellingShingle Multidisciplinary
Somjing Roongjang
Umaporn Pusod
Prapart Phooviang
Khesorn Nantachit
Development of method for determination of lead, iodine, and protein content in fish sauce
description The aim of this investigation was to develop a method for the determination of the lead, iodine, and protein content in fish sauce. For statistical data, five samples of fish sauce that cost 9.0-43.0 Bahts were randomly bought from a supermarket in Chiang Mai Province. Five replicates of each sample were digested and measured for the lead amount, using absorbance by atomic absorption spectroscopy, and each replication was injected six times. The iodine content were measured from the five samples, and each sample was investigated in five replications using the iodimetric method. The protein contents was determined by applying the Kjedahl method using the five samples. The lead determination method was accepted because of the statistical data. Using fish sauce as a seasoning agent is a practice that is safe from lead toxicity because the lead contents were found to be lower than the stipulated Thai Food Act Limit which is 1.0 ppm. The determination method for iodine content needs to be further developed by controlling the pH of the reaction medium to be neutral or to be that of a dilute acid. The protein determination method needs to be investigated for more statistical data. Consumers should also pay better attention to the sample label because it was observed in this investigation that there was a highly priced sample contained low nutritional values of protein besides showing the wrong label.
format Journal
author Somjing Roongjang
Umaporn Pusod
Prapart Phooviang
Khesorn Nantachit
author_facet Somjing Roongjang
Umaporn Pusod
Prapart Phooviang
Khesorn Nantachit
author_sort Somjing Roongjang
title Development of method for determination of lead, iodine, and protein content in fish sauce
title_short Development of method for determination of lead, iodine, and protein content in fish sauce
title_full Development of method for determination of lead, iodine, and protein content in fish sauce
title_fullStr Development of method for determination of lead, iodine, and protein content in fish sauce
title_full_unstemmed Development of method for determination of lead, iodine, and protein content in fish sauce
title_sort development of method for determination of lead, iodine, and protein content in fish sauce
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84963969157&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/53942
_version_ 1681424228829626368