Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to ma...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c http://cmuir.cmu.ac.th/handle/6653943832/5906 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-5906 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-59062014-08-30T03:23:36Z Performance of a portable near infrared instrument for Brix value determination of intact mango fruit Saranwong S. Sornsrivichai J. Kawano S. The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to make the calibration equations. It was found that the calibration equation using spectral data obtained with the FT20 had similar accuracy to that using Foss NIRSystems 6500 spectra. The SEPs of calibration equations were 0.40°Brix for both instruments. 2014-08-30T03:23:36Z 2014-08-30T03:23:36Z 2003 Article 09670335 http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c http://cmuir.cmu.ac.th/handle/6653943832/5906 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to make the calibration equations. It was found that the calibration equation using spectral data obtained with the FT20 had similar accuracy to that using Foss NIRSystems 6500 spectra. The SEPs of calibration equations were 0.40°Brix for both instruments. |
format |
Article |
author |
Saranwong S. Sornsrivichai J. Kawano S. |
spellingShingle |
Saranwong S. Sornsrivichai J. Kawano S. Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
author_facet |
Saranwong S. Sornsrivichai J. Kawano S. |
author_sort |
Saranwong S. |
title |
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
title_short |
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
title_full |
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
title_fullStr |
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
title_full_unstemmed |
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit |
title_sort |
performance of a portable near infrared instrument for brix value determination of intact mango fruit |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c http://cmuir.cmu.ac.th/handle/6653943832/5906 |
_version_ |
1681420513887387648 |