Performance of a portable near infrared instrument for Brix value determination of intact mango fruit

The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to ma...

Full description

Saved in:
Bibliographic Details
Main Authors: Saranwong S., Sornsrivichai J., Kawano S.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c
http://cmuir.cmu.ac.th/handle/6653943832/5906
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-5906
record_format dspace
spelling th-cmuir.6653943832-59062014-08-30T03:23:36Z Performance of a portable near infrared instrument for Brix value determination of intact mango fruit Saranwong S. Sornsrivichai J. Kawano S. The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to make the calibration equations. It was found that the calibration equation using spectral data obtained with the FT20 had similar accuracy to that using Foss NIRSystems 6500 spectra. The SEPs of calibration equations were 0.40°Brix for both instruments. 2014-08-30T03:23:36Z 2014-08-30T03:23:36Z 2003 Article 09670335 http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c http://cmuir.cmu.ac.th/handle/6653943832/5906 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description The performance of a commercially-available, portable NIR instrument "FT20" for fruit quality evaluation was investigated using mango fruits. The calibration result for the FT20 was compared with the result for the Foss NIRSystems 6500. Partial least squares (PLS) regression was used to make the calibration equations. It was found that the calibration equation using spectral data obtained with the FT20 had similar accuracy to that using Foss NIRSystems 6500 spectra. The SEPs of calibration equations were 0.40°Brix for both instruments.
format Article
author Saranwong S.
Sornsrivichai J.
Kawano S.
spellingShingle Saranwong S.
Sornsrivichai J.
Kawano S.
Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
author_facet Saranwong S.
Sornsrivichai J.
Kawano S.
author_sort Saranwong S.
title Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
title_short Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
title_full Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
title_fullStr Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
title_full_unstemmed Performance of a portable near infrared instrument for Brix value determination of intact mango fruit
title_sort performance of a portable near infrared instrument for brix value determination of intact mango fruit
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-0041376565&partnerID=40&md5=06425e7218619902a6218fa8ca0a398c
http://cmuir.cmu.ac.th/handle/6653943832/5906
_version_ 1681420513887387648