Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator

In this study, a concept of using thermosyphon heat pipe to extract heat from water in a storage tank to generate cooling water was proposed. Heat pipe condenser was attached with an aluminum plate and acted as a thermal radiator while its evaporator was dipped in the water storage tank. Cooling wat...

Full description

Saved in:
Bibliographic Details
Main Authors: Nammont Chotivisarut, Tanongkiat Kiatsiriroat
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75849140730&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59537
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-59537
record_format dspace
spelling th-cmuir.6653943832-595372018-09-10T03:16:55Z Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator Nammont Chotivisarut Tanongkiat Kiatsiriroat Energy In this study, a concept of using thermosyphon heat pipe to extract heat from water in a storage tank to generate cooling water was proposed. Heat pipe condenser was attached with an aluminum plate and acted as a thermal radiator while its evaporator was dipped in the water storage tank. Cooling water in the tank could be produced during the nighttime and used to serve the cooling load in a room during the daytime. A heat transfer model to calculate the water temperature and the room temperature during both the nighttime and daytime was developed. The input data were ambient temperature, dew point temperature, area of the radiator, volume of cooling water and room cooling load. The experiment was setup to verify the heat transfer model. A 9.0m2 tested room with six cooling coils, each of 0.87m2 was installed at the ceiling, was constructed along with the 1.0m3 water storage tank. A 500-2000W adjustable heater was taken as an artificial load inside the room. A 6.36m2 radiator is installed on a 45° tilting roof of the tested room. The simulated results agreed very well with those of the experimental data. With the developed model, a simulation to find the sizing of the radiator area and the volume of cooling water for cooling water production during winter of Chiang Mai, Thailand was carried out. The cooling water was used for cooling during summer in an air-conditioned room with different cooling loads. The parameters in terms of room temperature, radiator area, volume of cooling water, cooling load and UA of cooling coil were considered to carry out the percent of cooling load reduction. Copyright © 2009 John Wiley & Sons, Ltd. 2018-09-10T03:16:55Z 2018-09-10T03:16:55Z 2009-12-01 Journal 1099114X 0363907X 2-s2.0-75849140730 10.1002/er.1543 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75849140730&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/59537
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
Nammont Chotivisarut
Tanongkiat Kiatsiriroat
Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
description In this study, a concept of using thermosyphon heat pipe to extract heat from water in a storage tank to generate cooling water was proposed. Heat pipe condenser was attached with an aluminum plate and acted as a thermal radiator while its evaporator was dipped in the water storage tank. Cooling water in the tank could be produced during the nighttime and used to serve the cooling load in a room during the daytime. A heat transfer model to calculate the water temperature and the room temperature during both the nighttime and daytime was developed. The input data were ambient temperature, dew point temperature, area of the radiator, volume of cooling water and room cooling load. The experiment was setup to verify the heat transfer model. A 9.0m2 tested room with six cooling coils, each of 0.87m2 was installed at the ceiling, was constructed along with the 1.0m3 water storage tank. A 500-2000W adjustable heater was taken as an artificial load inside the room. A 6.36m2 radiator is installed on a 45° tilting roof of the tested room. The simulated results agreed very well with those of the experimental data. With the developed model, a simulation to find the sizing of the radiator area and the volume of cooling water for cooling water production during winter of Chiang Mai, Thailand was carried out. The cooling water was used for cooling during summer in an air-conditioned room with different cooling loads. The parameters in terms of room temperature, radiator area, volume of cooling water, cooling load and UA of cooling coil were considered to carry out the percent of cooling load reduction. Copyright © 2009 John Wiley & Sons, Ltd.
format Journal
author Nammont Chotivisarut
Tanongkiat Kiatsiriroat
author_facet Nammont Chotivisarut
Tanongkiat Kiatsiriroat
author_sort Nammont Chotivisarut
title Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
title_short Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
title_full Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
title_fullStr Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
title_full_unstemmed Cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
title_sort cooling load reduction of building by seasonal nocturnal cooling water from thermosyphon heat pipe radiator
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75849140730&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59537
_version_ 1681425269665038336