Analysis of power system event using synchronized PMUs in Thailand power network

This paper applies the synchronized phasor measurement units (PMUs) based wide-area monitoring system to analyze the power system event under the occurrence of large disturbance. The salient feature of the monitoring system is the convenient installation of PMU at 220 V home outlet. The power system...

Full description

Saved in:
Bibliographic Details
Main Authors: I. Ngamroo, A. Kunakorn, M. Leelajindakrirerk, Y. Mitani, S. Dechanupapritta, M. Watanabe, P. Jintakosonwit, T. Hashiguchi, Y. Ota, H. Ukai, J. Sakulrat, A. Sode-Yome, T. Tanasaksiri
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=54949112868&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61048
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61048
record_format dspace
spelling th-cmuir.6653943832-610482018-09-10T04:03:43Z Analysis of power system event using synchronized PMUs in Thailand power network I. Ngamroo A. Kunakorn M. Leelajindakrirerk Y. Mitani S. Dechanupapritta M. Watanabe P. Jintakosonwit T. Hashiguchi Y. Ota H. Ukai J. Sakulrat A. Sode-Yome T. Tanasaksiri Energy Engineering This paper applies the synchronized phasor measurement units (PMUs) based wide-area monitoring system to analyze the power system event under the occurrence of large disturbance. The salient feature of the monitoring system is the convenient installation of PMU at 220 V home outlet. The power system event given here is the tripping of High-Voltage Direct Current (HVDC) link between Thailand and Malaysia due to the fault in a thyristor room at Khlong Ngae converter station of Thailand side on July 22, 2005. The discrete wavelet decomposition and short-time Fourier Transform have been applied to analyze the characteristic of the inter-area oscillation between central and southern areas in both time and frequency domains. Analyzed results based on PMUs data are consistent with the actual tie-line power flow between both areas. 2018-09-10T04:03:14Z 2018-09-10T04:03:14Z 2007-12-01 Conference Proceeding 2-s2.0-54949112868 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=54949112868&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61048
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
Engineering
spellingShingle Energy
Engineering
I. Ngamroo
A. Kunakorn
M. Leelajindakrirerk
Y. Mitani
S. Dechanupapritta
M. Watanabe
P. Jintakosonwit
T. Hashiguchi
Y. Ota
H. Ukai
J. Sakulrat
A. Sode-Yome
T. Tanasaksiri
Analysis of power system event using synchronized PMUs in Thailand power network
description This paper applies the synchronized phasor measurement units (PMUs) based wide-area monitoring system to analyze the power system event under the occurrence of large disturbance. The salient feature of the monitoring system is the convenient installation of PMU at 220 V home outlet. The power system event given here is the tripping of High-Voltage Direct Current (HVDC) link between Thailand and Malaysia due to the fault in a thyristor room at Khlong Ngae converter station of Thailand side on July 22, 2005. The discrete wavelet decomposition and short-time Fourier Transform have been applied to analyze the characteristic of the inter-area oscillation between central and southern areas in both time and frequency domains. Analyzed results based on PMUs data are consistent with the actual tie-line power flow between both areas.
format Conference Proceeding
author I. Ngamroo
A. Kunakorn
M. Leelajindakrirerk
Y. Mitani
S. Dechanupapritta
M. Watanabe
P. Jintakosonwit
T. Hashiguchi
Y. Ota
H. Ukai
J. Sakulrat
A. Sode-Yome
T. Tanasaksiri
author_facet I. Ngamroo
A. Kunakorn
M. Leelajindakrirerk
Y. Mitani
S. Dechanupapritta
M. Watanabe
P. Jintakosonwit
T. Hashiguchi
Y. Ota
H. Ukai
J. Sakulrat
A. Sode-Yome
T. Tanasaksiri
author_sort I. Ngamroo
title Analysis of power system event using synchronized PMUs in Thailand power network
title_short Analysis of power system event using synchronized PMUs in Thailand power network
title_full Analysis of power system event using synchronized PMUs in Thailand power network
title_fullStr Analysis of power system event using synchronized PMUs in Thailand power network
title_full_unstemmed Analysis of power system event using synchronized PMUs in Thailand power network
title_sort analysis of power system event using synchronized pmus in thailand power network
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=54949112868&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61048
_version_ 1681425548577865728