Multi-link Vision and MiniVision stent registry in Asian patients with coronary artery disease: A prospective, multi-center study

Background: Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare meta...

Full description

Saved in:
Bibliographic Details
Main Authors: Yae Wei Xu, Yi Dong Wei, Kai Tang, Yan Qing Chen, Wei Ming Li, Xue Jing Yu, Yong Wen Qin, Gou Xian Qi, Peng Qu, Yu Qing Hou, Ashok Jain, Parvez Grant, Gudapati Ramesh, Basavappa Ramesh, Chumpol Piamsomboon, Srun Kuanprasert, Hyeon Cheol Gwon, Yoon Haeng Cho, Haizal Haroon Kamar, Cong Xin Huang
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547533727&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61300
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Description
Summary:Background: Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare metal stents (BMS)-Multi-link (ML) Vision/ML MiniVision stents. The clinical outcomes of Asian patients with coronary artery disease (CAD) after implanting the Multi-link Vision or MiniVision stent were investigated in this study. Methods: An observational, prospective, multi-center, non-randomized post marketing registry was conducted to demonstrate the efficacy of the BMS-ML Vision/ML MiniVision stents. The primary end point of the registry was clinical target lesion revascularization (TLR) at a 6-month follow-up. The major secondary end points included the rate of major adverse cardiac events (MACE) and serious adverse events (SAE) in hospital and at 6 months; and the rate of clinical TLR as a function of the type of angina. A total of 429 Asian people with 449 lesions from 14 centers were selected for this study. The average reference diameter of the lesions was (3.0±0.5) mm, and the mean length was (15.7±5.0) mm. Results: The successful rate of the procedure was 99.3%. Twenty-five percent of the lesions were treated by direct stenting without pre-dilation. Eighty-six percent of the lesions were implanted with ML Vision stent. After the 6-month follow-up, the rate of clinical TLR was 1.4%. The MACE, SAE and target vessel revascularization (TVR) were 6.8%, 3.5% and 1.4% respectively. Conclusion: The current registry showed the excellent 6-month clinical outcomes of ML Vision/ML MiniVision stents in Asian patients with CAD.