Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines
This paper presents the analysis of lightning overvoltages of 22 kV. overhead distribution line underbuilt on 115 kV. transmission line circuit to investigate the options for increasing the lightning performance. Improvement efforts could include better grounding, higher critical flashover voltage (...
Saved in:
Main Author: | |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33847218311&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61657 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-61657 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-616572018-09-11T08:56:37Z Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines Thanaphong Thanasaksiri Engineering This paper presents the analysis of lightning overvoltages of 22 kV. overhead distribution line underbuilt on 115 kV. transmission line circuit to investigate the options for increasing the lightning performance. Improvement efforts could include better grounding, higher critical flashover voltage (CFO) and arresters installation. The analysis of lightning overvoltages are performed using ATPDraw version of ElectroMagnetic Transients Program (EMTP). Models of system studied have also been presented. 2018-09-11T08:56:37Z 2018-09-11T08:56:37Z 2006-12-01 Conference Proceeding 2-s2.0-33847218311 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33847218311&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61657 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Engineering |
spellingShingle |
Engineering Thanaphong Thanasaksiri Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
description |
This paper presents the analysis of lightning overvoltages of 22 kV. overhead distribution line underbuilt on 115 kV. transmission line circuit to investigate the options for increasing the lightning performance. Improvement efforts could include better grounding, higher critical flashover voltage (CFO) and arresters installation. The analysis of lightning overvoltages are performed using ATPDraw version of ElectroMagnetic Transients Program (EMTP). Models of system studied have also been presented. |
format |
Conference Proceeding |
author |
Thanaphong Thanasaksiri |
author_facet |
Thanaphong Thanasaksiri |
author_sort |
Thanaphong Thanasaksiri |
title |
Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
title_short |
Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
title_full |
Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
title_fullStr |
Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
title_full_unstemmed |
Methods of improving the lightning performance of 22 kV circuit underbuilt on 115 kV transmission lines |
title_sort |
methods of improving the lightning performance of 22 kv circuit underbuilt on 115 kv transmission lines |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33847218311&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61657 |
_version_ |
1681425661468606464 |