Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry
A procedure for simultaneous separation/preconcentration of cadmium in water river samples, based on cloud point extraction (CPE) as a prior step to its determination by spectrophotometric method in a ternary ion association system has been developed for river water samples. The preconcentration was...
Saved in:
Main Authors: | , |
---|---|
Format: | บทความวารสาร |
Language: | English |
Published: |
Science Faculty of Chiang Mai University
2019
|
Online Access: | http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7371 http://cmuir.cmu.ac.th/jspui/handle/6653943832/63810 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-63810 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-638102019-05-07T09:57:20Z Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry Shahram Nekouei Farzin Nekouei A procedure for simultaneous separation/preconcentration of cadmium in water river samples, based on cloud point extraction (CPE) as a prior step to its determination by spectrophotometric method in a ternary ion association system has been developed for river water samples. The preconcentration was applied using simultaneous [Cd (SCN4)]-2 complexation and forming ternary ion association system with Toluidine Blue-O (TBO) and cationic surfactant N-cetyl-N-N-N-trimethyl ammonium bromide (CTAB), accordingly. The hydrophobic complex was quantitatively entrapped with octylphenoxy- polyethoxyethanol (Triton X-114) from aqueous solution. The parameters affecting the extraction efciency of the proposed method, such as sample pH, complexing agent concentration (SCN-,TBO+ and CTAB), buffer amount, ionic and non ionic surfactant concentration, temperature, and incubation time were optimized. The relative standard deviation (RSD) for nine replicate determinations at 50 mg L-1 of cadmium was 3.11%. The resultant limit of detection (LOD) and limit of quantification (LOQ) were 2.1 and 7 mg L-1, respectively. The calibration graph was linear with a correlation coefcient of 0.9985 in the range of 7-1000 mg L-1 of cadmium. 2019-05-07T09:57:20Z 2019-05-07T09:57:20Z 2016 บทความวารสาร 0125-2526 http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7371 http://cmuir.cmu.ac.th/jspui/handle/6653943832/63810 Eng Science Faculty of Chiang Mai University |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
A procedure for simultaneous separation/preconcentration of cadmium in water river samples, based on cloud point extraction (CPE) as a prior step to its determination by spectrophotometric method in a ternary ion association system has been developed for river water samples. The preconcentration was applied using simultaneous [Cd (SCN4)]-2 complexation and forming ternary ion association system with Toluidine Blue-O (TBO) and cationic surfactant N-cetyl-N-N-N-trimethyl ammonium bromide (CTAB), accordingly. The hydrophobic complex was quantitatively entrapped with octylphenoxy- polyethoxyethanol (Triton X-114) from aqueous solution. The parameters affecting the extraction efciency of the proposed method, such as sample pH, complexing agent concentration (SCN-,TBO+ and CTAB), buffer amount, ionic and non ionic surfactant concentration, temperature, and incubation time were optimized. The relative standard deviation (RSD) for nine replicate determinations at 50 mg L-1 of cadmium was 3.11%. The resultant limit of detection (LOD) and limit of quantification (LOQ) were 2.1 and 7 mg L-1, respectively. The calibration graph was linear with a correlation coefcient of 0.9985 in the range of 7-1000 mg L-1 of cadmium. |
format |
บทความวารสาร |
author |
Shahram Nekouei Farzin Nekouei |
spellingShingle |
Shahram Nekouei Farzin Nekouei Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
author_facet |
Shahram Nekouei Farzin Nekouei |
author_sort |
Shahram Nekouei |
title |
Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
title_short |
Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
title_full |
Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
title_fullStr |
Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
title_full_unstemmed |
Determination of Cadmium at Trace Levels in River Water Samples by Simultaneous Ion-Pairing and Mixed Micelle Extraction Prior to UV-Vis Spectrophotometry |
title_sort |
determination of cadmium at trace levels in river water samples by simultaneous ion-pairing and mixed micelle extraction prior to uv-vis spectrophotometry |
publisher |
Science Faculty of Chiang Mai University |
publishDate |
2019 |
url |
http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7371 http://cmuir.cmu.ac.th/jspui/handle/6653943832/63810 |
_version_ |
1681425964547964928 |