Is driving oxygen flow rate clinically important for nebulizer therapy in patients with COPD?

Our study suggests that the administration of bronchodilator drug via nebulizer powered by flow rate 6 L/min is more suitable in COPD patients. The oxygen flow rates should not be given more than 6 L/min. In this study, we recruited COPD patients in a stable stage, in whom the risk of hyperoxic indu...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Charoenratanakul, K. Borrirukwanit, W. Satayawiwat, S. Lekuthai, W. Dejsomritrutai
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/17349
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University