A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography

The internal jugular (IJ) valve is the only valve between the heart and the brain, preventing venous reflux into the IJ vein. Internal jugular valve competence has been tested by IJ venography, Doppler ultrasonography of the IJ vein and M-mode ultrasonography of the IJ valve, and color flow imaging...

Full description

Saved in:
Bibliographic Details
Main Authors: Disya Ratanakorn, Paul E. Tesh, Charles H. Tegeler
Other Authors: Wake Forest University School of Medicine
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/25752
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.25752
record_format dspace
spelling th-mahidol.257522018-09-07T16:00:47Z A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography Disya Ratanakorn Paul E. Tesh Charles H. Tegeler Wake Forest University School of Medicine Mahidol University Wake Forest University Baptist Medical Center Medicine The internal jugular (IJ) valve is the only valve between the heart and the brain, preventing venous reflux into the IJ vein. Internal jugular valve competence has been tested by IJ venography, Doppler ultrasonography of the IJ vein and M-mode ultrasonography of the IJ valve, and color flow imaging (CFI) of the IJ vein. However, interpretation of venous Doppler and CFI is difficult, and venography is invasive. The purpose of this study was to evaluate the feasibility of a new dynamic method to test IJ valve competency, and to review the literature regarding the potential clinical importance of this pathophysiology. Ten patients had intravenous injection of agitated air and saline during Valsalva maneuver with B-mode monitoring and CFI of the right IJ vein. Contrast bubbles were clearly identified refluxing into the right IJ vein in 50% of patients. Air contrast studies more often showed IJ valve incompetence than CFI. Bubbles appeared in the IJ vein within 19.2 sec and persisted up to 282 sec. Bubble aggregation was also observed. There was no correlation between positive bubbles and the presence of spontaneous echo contrast on baseline B-mode imaging. Air contrast ultrasound venography (ACUV) is a new noninvasive method to assess competency of the IJ valves. This technique is feasible, appears to be more sensitive than CFI, and adds a new dimension to the study of the venous system in cerebrovascular disease. Potential clinical application includes evaluation of patients with increased central venous pressure, those with morning headaches, and those on positive end-expiratory pressure ventilators. 2018-09-07T09:00:47Z 2018-09-07T09:00:47Z 1999-01-01 Article Journal of Neuroimaging. Vol.9, No.1 (1999), 10-14 10.1111/jon19999110 10512284 2-s2.0-0032938058 https://repository.li.mahidol.ac.th/handle/123456789/25752 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0032938058&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Disya Ratanakorn
Paul E. Tesh
Charles H. Tegeler
A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
description The internal jugular (IJ) valve is the only valve between the heart and the brain, preventing venous reflux into the IJ vein. Internal jugular valve competence has been tested by IJ venography, Doppler ultrasonography of the IJ vein and M-mode ultrasonography of the IJ valve, and color flow imaging (CFI) of the IJ vein. However, interpretation of venous Doppler and CFI is difficult, and venography is invasive. The purpose of this study was to evaluate the feasibility of a new dynamic method to test IJ valve competency, and to review the literature regarding the potential clinical importance of this pathophysiology. Ten patients had intravenous injection of agitated air and saline during Valsalva maneuver with B-mode monitoring and CFI of the right IJ vein. Contrast bubbles were clearly identified refluxing into the right IJ vein in 50% of patients. Air contrast studies more often showed IJ valve incompetence than CFI. Bubbles appeared in the IJ vein within 19.2 sec and persisted up to 282 sec. Bubble aggregation was also observed. There was no correlation between positive bubbles and the presence of spontaneous echo contrast on baseline B-mode imaging. Air contrast ultrasound venography (ACUV) is a new noninvasive method to assess competency of the IJ valves. This technique is feasible, appears to be more sensitive than CFI, and adds a new dimension to the study of the venous system in cerebrovascular disease. Potential clinical application includes evaluation of patients with increased central venous pressure, those with morning headaches, and those on positive end-expiratory pressure ventilators.
author2 Wake Forest University School of Medicine
author_facet Wake Forest University School of Medicine
Disya Ratanakorn
Paul E. Tesh
Charles H. Tegeler
format Article
author Disya Ratanakorn
Paul E. Tesh
Charles H. Tegeler
author_sort Disya Ratanakorn
title A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
title_short A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
title_full A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
title_fullStr A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
title_full_unstemmed A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
title_sort new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/25752