POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM

Blackout that occurs in Bengkulu subsystem at February 15th 2017 was triggered by single phase ground fault in line near Lubuk Linggau substation 150 kV. The line clearing caused an islanding operation for Bengkulu subsystem from the South Sumatera Grid. This situation caused the small size generato...

Full description

Saved in:
Bibliographic Details
Main Author: SATYA DINI (NIM. 23216116), HASNA
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/22397
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:22397
spelling id-itb.:223972017-09-27T15:37:42ZPOST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM SATYA DINI (NIM. 23216116), HASNA Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/22397 Blackout that occurs in Bengkulu subsystem at February 15th 2017 was triggered by single phase ground fault in line near Lubuk Linggau substation 150 kV. The line clearing caused an islanding operation for Bengkulu subsystem from the South Sumatera Grid. This situation caused the small size generator which supported Bengkulu subsystem ran in unstable condition and had to be pulled out from the system. Power deficit in the Bengkulu area subsystem triggered the defense scheme to operate, resulting in under frequency relay operation until its first step. The defense scheme caused power oscillation to increase in several seconds due to small damping in the subsystem. Several minutes later, the medium size generator which supported Bengkulu subsystem ran in oscillation without damping, and collapsed. This paper deals with a root cause analysis to this blackout events for each state of the Bengkulu subsystem. The result of this analysis show that some local oscillation happened due to lack of proper control setting in last generators. The approach to found the root cause of blackout is based on modal analysis of small signal dynamic stability and calculate of the participation factor related to the unstable modes. Based on finding of oscillation mode and its state participation factor, an implementation of power system stabilizer with proper tuning is introduced to improve the stability in Bengkulu subsystem. The result of simulation shows that with good and proper setting of PSS tuning the sub system Bengkulu will be survive to similar event in the grid. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Blackout that occurs in Bengkulu subsystem at February 15th 2017 was triggered by single phase ground fault in line near Lubuk Linggau substation 150 kV. The line clearing caused an islanding operation for Bengkulu subsystem from the South Sumatera Grid. This situation caused the small size generator which supported Bengkulu subsystem ran in unstable condition and had to be pulled out from the system. Power deficit in the Bengkulu area subsystem triggered the defense scheme to operate, resulting in under frequency relay operation until its first step. The defense scheme caused power oscillation to increase in several seconds due to small damping in the subsystem. Several minutes later, the medium size generator which supported Bengkulu subsystem ran in oscillation without damping, and collapsed. This paper deals with a root cause analysis to this blackout events for each state of the Bengkulu subsystem. The result of this analysis show that some local oscillation happened due to lack of proper control setting in last generators. The approach to found the root cause of blackout is based on modal analysis of small signal dynamic stability and calculate of the participation factor related to the unstable modes. Based on finding of oscillation mode and its state participation factor, an implementation of power system stabilizer with proper tuning is introduced to improve the stability in Bengkulu subsystem. The result of simulation shows that with good and proper setting of PSS tuning the sub system Bengkulu will be survive to similar event in the grid.
format Theses
author SATYA DINI (NIM. 23216116), HASNA
spellingShingle SATYA DINI (NIM. 23216116), HASNA
POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
author_facet SATYA DINI (NIM. 23216116), HASNA
author_sort SATYA DINI (NIM. 23216116), HASNA
title POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
title_short POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
title_full POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
title_fullStr POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
title_full_unstemmed POST DISTURBANCE ANALYSIS OF BLACKOUT IN BENGKULU SUBSYSTEM
title_sort post disturbance analysis of blackout in bengkulu subsystem
url https://digilib.itb.ac.id/gdl/view/22397
_version_ 1821120758631366656