ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK

<b>Abstrack</b><p align=\"justify\"> <br /> During CO2 desorption from benfield solution, several tubes of reboiler were significantly thinning and leaking after about 6 years in service than estimated the technical design 20 years. The failure location at tubes at...

Full description

Saved in:
Bibliographic Details
Main Author: Hardjono, Priatmo
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/5313
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:5313
spelling id-itb.:53132006-02-28T09:54:22ZANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK Hardjono, Priatmo Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Theses <br><i>Failure analysis, Ammonia factory, PT Kujang</br></i> INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/5313 <b>Abstrack</b><p align=\"justify\"> <br /> During CO2 desorption from benfield solution, several tubes of reboiler were significantly thinning and leaking after about 6 years in service than estimated the technical design 20 years. The failure location at tubes at the point in front of the outlet condensate closed at the location of the inlet LTS effluent. <br /> <br /> Inspection using optical microscops as wen as leaking tests and thickness measurement using eddy current technique have also been conducted to measure the damage level of the tubes. The chemical composition of corrosion product was determined using EDAX and it was found that the corrosion product contained significant chloride. <br /> <br /> Tube materials is made by austenitic stainless steel AISI 304 L (A-249 TP 304) which is unlikely to be sensitized during welding. It is thought that this failure caused by SCC intergranular due to the accumulation of condensed chloride on the tube at the vapor phase zone. The reccomended of subtitute tube materials that resistance to the condition is stailess steel super duplex ferritik-austenitik. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Hardjono, Priatmo
ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
description <b>Abstrack</b><p align=\"justify\"> <br /> During CO2 desorption from benfield solution, several tubes of reboiler were significantly thinning and leaking after about 6 years in service than estimated the technical design 20 years. The failure location at tubes at the point in front of the outlet condensate closed at the location of the inlet LTS effluent. <br /> <br /> Inspection using optical microscops as wen as leaking tests and thickness measurement using eddy current technique have also been conducted to measure the damage level of the tubes. The chemical composition of corrosion product was determined using EDAX and it was found that the corrosion product contained significant chloride. <br /> <br /> Tube materials is made by austenitic stainless steel AISI 304 L (A-249 TP 304) which is unlikely to be sensitized during welding. It is thought that this failure caused by SCC intergranular due to the accumulation of condensed chloride on the tube at the vapor phase zone. The reccomended of subtitute tube materials that resistance to the condition is stailess steel super duplex ferritik-austenitik.
format Theses
author Hardjono, Priatmo
author_facet Hardjono, Priatmo
author_sort Hardjono, Priatmo
title ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
title_short ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
title_full ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
title_fullStr ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
title_full_unstemmed ANALISIS KEGAGALAN REBOILER 1114-CA PABRIK AMMONIA PT. PUPUK KUJANG CIKAMPEK
title_sort analisis kegagalan reboiler 1114-ca pabrik ammonia pt. pupuk kujang cikampek