USE OF BORED PILED AS A METHOD OF STRENGTHENING BUILDING FOUNDATIONS.CASE STUDY : MARGATIGA DAM, LAMPUNG
The design of a dam must meet four main criteria: being safe from structural failure, safe from hydraulic failure, safe from failure due to seepage, and safe from operational and maintenance failures of the dam (Centre for Education and Training in Water Resources and Construction, 2017). The det...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/75321 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | The design of a dam must meet four main criteria: being safe from structural failure,
safe from hydraulic failure, safe from failure due to seepage, and safe from operational
and maintenance failures of the dam (Centre for Education and Training in Water
Resources and Construction, 2017). The determination of the foundation structure must
take into account the geological or subsurface rock conditions and the structural loads
that must be borne by the foundation. The purpose of this study is to determine the type
of foundation needed based on the correlation between subsurface conditions and the
type of structural load that the foundation will carry and to provide analysis regarding
the type of foundation used as reinforcement in buildings. The analytical method is
carried out by in-situ tests in the form of Pressure Metre tests (PMT) and Standard
Penetration tests (SPT), as well as the calculation of foundation bearing capacity
analysis using bore piles. PMT results show that PMT 1, or the location of the intake
gate area, has a maximum pressure value of 0.16–1.22 MPa, PMT 2, or the spillway
area, has a maximum pressure value of 2.57–7.40 MPa, and PMT 3, or DPT Right, has
a maximum pressure value of 0.63–5.2 MPa. The SPT results show that rock with dense
density is found in tuffaceous sandstone layers with an SPT value of >50 at the intake
gate area at an elevation of -2.159, the spillway area at an elevation of +1.23, and the
right DPT area at an elevation of 0.0. The results of the calculation of the bore pile
foundation with a safety factor of 2.5 show that the total piles needed at the intake area
are 156 piles, the Spillway 1 and 2 areas are 196 piles, and the Right DPT area is 64
piles. |
---|